Installation Requirements
The cup warming drawer can be installed in a standard or
flush inset application. Finish the edges of the opening.
They may be visible when the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For flush inset installations, a minimum
1
/
8
"
(3)
reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the cup
warming drawer from tipping forward when opened.
INSTALLATION REQUIREMENTS
BASE SUPPORT
MIN
Cup Warming Drawer
75 lb
(34 kg)
TRIM OVERLAP
Top
0"
(0)
Bottom
0"
(0)
Sides
11
/
16
"
(18)
COMBINATION INSTALLATION
To install a cup warming drawer below a coffee system,
one opening for both units must be specified. To achieve
the minimum reveal between units, place the coffee system
support rails on top of the cup warming drawer, then secure
the rails to the sides of the cabinet. Any material between
the units will increase the horizontal reveal.
Installation of an anti-tip block is not necessary when the
cup warming drawer is installed below a coffee system.
SPECIFICATIONS
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit, servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
grounded, 120 VAC, 60 Hz
Service
10 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
3'
(.9 m)
Rating plate location.
RATING
PLATE