Cooktop Low-Profile Hood Installation
11
wolfappliance.com/specs
Wall Hoods—Ducted Installation
Fit 6"
(152)
metal ducting (not provided) to the air vent of
the hood and seal with duct tape. Refer to illus 5 below.
For exhaust hoods, turn the upper flue over so that the air
exhaust grid is in the lower section.
WIRING CONNECTIONS
Electrical connection at the hood:
1)
Run Romex
®
wire from the service panel to the hood’s
electrical box marked ‘120 V AC input’.
2)
Remove the cover from the electrical box and remove
one knockout as shown in illus 6.
3)
Secure the Romex
®
wire to the electrical box through a
conduit connector. Use wire connectors or wire nuts
approved by UL or C/UL.
4)
Make electrical connections at the hood. Connect
white to white, black to black and green to ground.
5)
Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
DUCTING
Illus 5.
Illus 6.
WIRING
BOX
IN-LINE OR REMOTE BLOWER WIRING
Blower connection at the hood:
1)
Run Romex
®
wire from the in-line or remote blower to
the hood’s electrical box marked ‘motor connection’.
2)
Remove the cover from the electrical box and remove
one knockout as shown in illus 7 below.
3)
Secure the Romex
®
wire to the electrical box through a
conduit connector. Use wire connectors or wire nuts
approved by UL or C/UL.
4)
Make electrical connections at the hood. Connect
white to red, black to black and green to ground.
5)
Place all wiring connections inside the electrical box
and reinstall the cover. Make sure all wires are secure
and that no wires are pinched between the cover and
electrical box.
IMPORTANT NOTE:
Refer to installation instructions
provided with the in-line or remote blower assembly for
additional mounting and wiring instructions.
ATTACH FLUE EXTENSION
Insert the flue extensions, setting them on the hood.
Extend the upper flue to the ceiling and secure with two
screws as shown in illus 8.
WIRING
BOX
Illus 7.
Illus 8.
SCREWS