30
3062347_0309
The excess temperature differential between the cylinder temperature and the
boiler water temperature during cylinder heating is selected with parameter
HG25. This ensures that, even in spring and autumn, the boiler water
temperature is higher than the cylinder temperature, thereby ensuring short
heating times.
Boiler overtemperature during
DHW cylinder heating
Parameter HG25
HG25
20
Factory setting: 20 K
Setting range: 0 to 40 K
Displaying / modifying control parameters
with Wolf control accessories
Parameters
HG 80
Fault 1
HG 81
Fault 2
HG 82
Fault 3
HG 83
Fault 4
HG 84
Fault 5
HG 85
Fault 6
HG 86
Fault 7
HG 87
Fault 8
HG 88
Fault 9
HG 89
Fault 10
HG70
54
Display only:
With parameter HG70 analogue input E1 is displayed, if a manifold sensor is
connected (display only).
HG80
04
Display only:
Fault history
Parameter HG80
Содержание CGG-2-18
Страница 64: ...64 3062347_0309 Notes ...