2 7
3062087_0207
Conversion to other gas types
ON / OFF switch
ON / OFF
DHW
temperature
selector
Pressure
gauge
Reset
button
Heating water
temperature selector
Illuminated
signal ring
Thermometer
- At the system ON / OFF switch, switch the boiler first OFF
and then ON again. There must not be any fault present at the
boiler.
- Press the reset button (within the following 30 seconds) and
it hold down during the next steps.
- After 5 seconds, the illuminated signal ring indicates the
currently selected gas type (see table adjusting the gas type).
- Turn the heating water temperature selector towards the
required gas type and check the setting by means of the colour
of the illuminated signal ring (see table adjusting the gas type).
- The adjustment will only be activated when the reset button is
released.
- A successful conversion of the gas type is indicated by a triple
flashing (yellow/red) of the signal ring.
Gas type
Natural gas
LPG
Signal ring
quickly flashing yellow
quickly flashing red
Heating water temperature adjustment
l.h. end stop
r.h. end stop
Table: Adjusting the gas type
2. Adjusting the control unit:
Check the nozzle pressure after converting
the gas type, otherwise material losses and
incorrect functions can occur.
NB