6. Rooftop installation
(interlocking tile, plain tile)
Distribute all roof hooks supplied evenly over the width of the collector
array to spread the loads applied. For this, position the roof hooks as
near to the rafters as possible.
NB
Positioning the collector
array for rooftop
installation
NB:
No consideration has been given to the installation location or the pipe
connections.
Standard dimensions for
determining the width of the
collector array
Standard delivery, fixing material
subject to the number of:
Top roof hooks
with fixing brackets
Bottom roof hooks
with fixing brackets
Mounting rail
Mounting rail joint
set (if required)
Screws, nuts, grub
screws, woodscrews
in a bag
Compensating
rail set with
woodscrews for
mounting on rafters
Accessories
Number of collectors
1
2
3
4
5
6
7
8
9
10
Width [m] installation on end
X
2.23
3.36
4.49
5.62
6.75
7.88
9.01 10.14 11.27
CFK-1
Without snow load extension set
With snow load extension set
Max. area loading
2.4 kN/m²
4 kN/m²
Snow load zone 1
1190 m above sea level
1561 m above sea level
Snow load zone 1a
1039 m above sea level
1374 m above sea level
Snow load zone 2
768 m above sea level
1027 m above sea level
Snow load zone 2a
663 m above sea level
896 m above sea level
Snow load zone 3
587 m above sea level
799 m above sea level
Max. snow load when installing flat-plate collectors on end with an inclination of 30° to 45°
This calculation takes a factor of 0.8 according to DIN 1055-5 into consideration (corresponding to a roof
inclination of 0° to 30°). We recommend roof integration where higher snow loads prevail.