background image

3

I N S TA L L AT I O N

R E Q U I R E M E N T S

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your
building.

Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.

If you cannot reach your gas
supplier, call the fire department.

W O L F

G A S C O O K T O P S

Installation to be carried out only
by an authorised person.

Do not modify this appliance.

A ventilation hood is recom-
mended for use with the Wolf gas
multi-function cooktop.

Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or any
other appliance.

The use of a gas cooking appliance
results in the production of heat
and moisture in the room in which
it is installed. Ensure that the
kitchen is well ventilated; keep
natural ventilation holes open or
install a mechanical ventilation
device (mechanical extractor
hood).

Prolonged intensive use of the
appliance may for additional venti-
lation, for example opening of a
window, or more effective ventila-
tion, for example increasing the
level of mechanical ventilation
where present.

This appliance shall be installed
in accordance with the regula-
tions in force and only used in a
well ventilated space. Read the
instructions before installing or
using this appliance.

Installer:

Please read the entire

Installation Instructions prior to

installation. Save these instructions

for the local inspector’s reference,

then leave them with the home-

owner.

Homeowner:

Please read and keep

these instructions for future refer-

ence and be sure to read the entire

Use & Care Information prior to use.

IMPORTANT NOTE:

be installed in accordance with the manufac-
turer’s installation instructions, local gas fitting

Australian Standard for gas installations. Refer

COOKTOPS installation manual:Intl Gas Cooktops Install  31/3/10  2:24 PM  Page 3

Not  suitable  for  use  in  marine  craft,  caravans  or  mobile  
h

omes,  unless  each  burner  is  fitted  with  a  flame  

s

afeguard.

Statutory requirements:

This appliance shall

also to AS5601 for gas pipe sizing tables.

regulations

  and  authority

, municipal building codes,

electrical

wiring regulations, and AS5601 the

Содержание CBCT15S

Страница 1: ...GAS COOKTOPS INSTALLATION INSTRUCTIONS Model numbers ICBCT36G S This cooktop is approved for use with Leave instructions with the owner ICBCT15G S ICBCT30G S Natural and Propane gases ...

Страница 2: ... would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Inc C O N TA C T I N F O R M AT I...

Страница 3: ...f the appliance may for additional venti lation for example opening of a window or more effective ventila tion for example increasing the level of mechanical ventilation where present This appliance shall be installed in accordance with the regula tions in force and only used in a well ventilated space Read the instructions before installing or using this appliance Installer Please read the entire...

Страница 4: ...st be available refer to Gas Supply Requirements on page 10 Electrical ground is required see Electrical Requirements on page 11 The adjustment conditions for this appli ance are stated on the label or rating plate The data plate can be found on the underside of the cooktop W O L F GAS COOKTOPS Rating plate location Location of rating plate under cooktop R AT I N G P L AT E I N F O R M AT I O N Mo...

Страница 5: ...p will be installed The location should be away from strong draft areas such as windows doors and strong heating vents or fans Do not obstruct flow of combustion and ventilation air This appliance is not connected to a combustion products evacuation device It shall be installed and connected in accor dance with current installation regulations Particular attention shall be given to the relevant re...

Страница 6: ...UNTERTOP HEIGHT 330 mm max 762 mm COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 64 mm 127 mm LOCATION OF GAS SUPPLY MAY ALSO EXTEND 127 mm ON FLOOR FROM BACK WALL FRONT OF COUNTERTOP 64 mm min 489 mm COOKTOP CUT OUT DEPTH W O L F GAS COOKTOPS Overall Dimensions Countertop Cut Out 381 mm OVERALL WIDTH 533 mm OVERALL DEPTH 102 mm M O D E L I C B C T 1 5 G S D I M E N S I O N S Overall Width 381 ...

Страница 7: ...er than 610 mm it is recommended that the electrical and gas supply be placed in the base cabinet to the right of the oven Refer to installation instructions provided with the built in oven for additional specifications If the Model ICBCT30G S is installed above cabinets the gas and electrical placement is not critical A grounded outlet needs to be placed within 1 2 m of the right rear of the cook...

Страница 8: ... mm COUNTERTOP TO COMBUSTIBLE MATERIALS ABOVE COOKTOP 610 mm min Minimum clearance from both side edges of cooktop cut out to combustible materials up to 457 mm above countertop Minimum clearance from rear edge of cooktop cut out to combustible materials up to 457 mm above countertop 889 mm COOKTOP CUT OUT WIDTH 889 mm COOKTOP CUT OUT WIDTH 991 mm RECOMMENDED CABINET WIDTH 914 mm min 102 mm 254 mm...

Страница 9: ...or gas supplier for confirmation of gas type The cooktop must be connected to the gas supply with upstream connection of an isolation valve in accor dance with the respectively valid regulations We recommend that the isolation valve be fitted prior to the cooktop to enable isolation of the cooktop from the gas supply The valve must be easily accessible at all times This appliance may be connected ...

Страница 10: ...gid pipe to the cooktop location A smaller size pipe on long runs may result in insufficient gas supply Pipe joint compounds suitable for use with LP gas should be used For LP gas piping or tubing size can be 13 mm minimum LP gas suppliers usually determine the size and materials used on the system If local codes permit a flexible metal appliance connector is recommended for connecting this cookto...

Страница 11: ... correct polarity A wiring diagram is This appliance when installed must be electri cally grounded in accordance with local codes The appliance is supplied with a cord and appliance can be hard wired to a terminal box or plug Do not remove ground prong Supply must be properly earthed failure to follow these instructions can result in electric shock fire or death female plug to connect to the appli...

Страница 12: ...ountertop opening Check that the cooktop is parallel to the front edge of the countertop Lift the entire cooktop to make adjustments and align the rear edge with the pencil line Attach the brackets to the burner box Insert the 89 mm clamping screws into the brackets Use a screwdriver to tighten the clamping screws against the underside of the counter top Refer to the illustration below Do not over...

Страница 13: ... before retrying to ignite the burner Ensure that the flames do not extinguish when you reduce to low flame quickly Check correct operation of each burner individually and in combination F L A M E H E I G H T A N D A P P E A R A N C E The flame on natural gas should be blue with a deeper blue core and no yellow tipping If burners show any abnormality check that burner heads are correctly located a...

Страница 14: ... a disruption in service For service call 1300 808 859 C O N TA C T I N F O R M AT I O N Website www multyflex com au I M P O R T E D D I S T R I B U T E D B Y MultyFlex Made in USA Electrical compliance in accordance with AS NZS3100 240 V AC 10 amps 50 Hz Imported distributed by Suite 1 151 Barkley Avenue Burnley VIC 3121 t 61 3 9421 0232 Model No ICBCT15G S Serial No Gas type NG LPG Test point p...

Страница 15: ... ICBCT15G S POWER CORD WHITE RIGHT FRONT BLACK RIV GAS VALVE RED RED RED RED WHITE GRN YEL BLACK RIGHT REAR LEFT REAR LEFT FRONT BLACK WHITE WHITE BLACK LEFT FRONT POWER CORD RED RIV GAS VALVE WHITE BLACK RIGHT REAR LEFT REAR RIGHT FRONT CTR REAR GRN YEL BLACK RED RED RED BLACK WHITE WIRING D I A G R A M S Model ICBCT30G S Model ICBCT36G S ...

Страница 16: ...Imported distributed by Multyflex www multyflex com au ...

Отзывы: