FULL SIZE GAS CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F32700 (February 2006)
Page 27 of 64
MENU
ALTERNATING ON
DISPLAY
PARAMETER
DATA
Celsius_Fahrenheit
C_F
F
Guard Band
gb
4000
Temperature
Compensation
tcnP
OFF
Input Type 1
InP1
J
Range Low 1
rL1
75
Range High 1
rH1
500
Hysteresis
HYS1
3
Calibration Offset
CAL1
0
Exit Setup Mode and
return to Operation
Mode.
set point temperature is
displayed or if call for
heat, dashes (----)
displayed.
Probe Test
1.
Set the control to 350
E
F.
2.
Access the back of the control panel to
disconnect the probe lead wires.
3.
Install a jumper wire across the probe terminals.
This will simulate room temperature.
A.
If the heat light comes on and the actual
temperature is room temperature, replace
the probe.
B.
If the heat light does not come on or the
actual temperature is not room
temperature, replace the control.
Solid State Relay Test
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
2.
Set the temperature to 350°F or high enough to
keep the heat ON for several minutes.
3.
Check for +5 VDC on input side of SSR
(terminals 3 & 4).
A.
If +5 VDC is present, continue to step 4.
B.
If no voltage is present, computer control is
not functioning properly.
4.
Check for 120 VAC at load side of SSR
(terminals 1 & 2).
A.
If no voltage is present, solid state relay is
not functioning properly.
1)
Replace the SSR and check for
proper operation.
B.
If 120 VAC is present, component is
functioning properly.
5.
Re-assemble oven and check for proper
operation.
COMPUTER CONTROL
CALIBRATION
(WKGC/WKGCX)
1.
Place a thermocouple in the geometric center of
the oven cavity.
2.
Set the ON-OFF-OVEN COOL switch to ON.
A.
If the set point temperature is 350°F,
proceed to step 4.
B.
If the set point temperature is other than
350°F, proceed to step 3 to change the
temperature.
3.
Press the set key then temperature key to enter
the temperature set mode.
A.
The display will alternate between the term
StPt (set point) and the current oven
temperature setting.
B.
Press the up or down arrow keys to make
the proper selection.
C.
Press the set key again to save the change
and exit the temperature set mode.
4.
Allow the oven temperature to stabilize
(normally 3 cycles).
5.
Compare the controls set point temperature to
the thermocouple meter reading when the heat
light goes out.
A.
A temperature variance more than 5°F
indicates an adjustment is needed.
1)
To make the adjustment, proceed to
step 6.
2)
If temperature variance is less than
5°F, computer control is functioning
properly.
6.
Enter the setup mode as outlined in SETUP
MODE under COMPUTER CONTROL
(WKGC/WKGCX).
A.
Advance through the menu until CAL1
(Calibration Offset) appears.
1)
If the thermocouple reading is higher
than set point temperature, press the
down arrow key and enter a negative
offset value that is equal to the
number of degrees above the 5°F
tolerance.
Содержание 126620
Страница 53: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F32700 February 2006 Page 53 of 64 ...
Страница 55: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F32700 February 2006 Page 55 of 64 ...
Страница 57: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F32700 February 2006 Page 57 of 64 ...
Страница 59: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F32700 February 2006 Page 59 of 64 ...
Страница 61: ...FULL SIZE GAS CONVECTION OVENS ELECTRICAL OPERATION F32700 February 2006 Page 61 of 64 ...