Wolf-Guard YL-007Z Скачать руководство пользователя страница 6

it is required to reset date and time after electrify every time in order to record 
alarm system info accurately.) 

7.

 

Setting Up Defence Zone 
Press the key

Area Set

on the panel under the disarming status, then press

【▲】

and

【↓】

to choose the right one you want to arm from 1-8 defence zone, press 

【#】

to

 

confirm. When the typeface “ type, place, detector” display on the 

screen , press

【▲】

and

【↓】

  to lock the your aim. The defence zone type include 

“ out, home, delay”. The system will skip to “delay” cursor enquiring if you 
want to set this zone as delay zone whichever you choose, out or home. Press

【#】

to comfirm and 

R

eturn】

to skip. Defence zone places include “ hall, 

bedroom, kitchen, sanctum, storehouse, balcony, passage, office, etc.”. Detectors 
include “ P.I.R , door magnet, panic, gas, smoke, etc.”. 

    8. Code for Detector 

Press the key

Code

 after press 

【#】 

to confirm the detector you want to code 

under the defense zone setup status. The detector icon will flash awaiting your 
fittings triggering. The panel will send out one beep to denote successful code. 
Please shut off the power of the previous detector, then go to the next fitting       
code i.e. switch on the P.I.R letting signal lamp light one time, stagger the door 
magnet transmit box and magnet letting signal lamp light one time. Continous   
beeps denote the detector is not suited.  Every defence zone could accept 
several detectors. (Attached detectors have been coded before selling , door 
magnets have been set as the first defense zone, stay defence, no delay, hall. The 
P.I.R is regarded as the second defence zone, out defence zone, no delay, 
bedroom). 

9.

 

  Remote Controller Code 

Press the key

program

on the panel under the disarming status, then press

【▲】

and

【↓】

to twinkle typeface “ Other Setup” , press

【#】

to confirm , press 

【▲】

and

【↓】

  to make “remote control code” twinkle, pressing

【#】

to comfirm 

entering remote control status. At last , press the 

Code

  to add your aim 

remote controller one by one during the icon “remote control code” flashing, it 
sends out one beep to confirm.( attached remote controller have been coded 
before selling) 

10. Intelligent Remote Control Switch Code 

      Press the key

Code

two times under the disarming status, main panel will 

enter the coding status, press random key of the remote controller of 
intelligent remote control switch.One beep denotes the successful 
code.( attached intelligent remote controller switch have been coded before 
selling) 

11.

 

Browse And History 
Press the key

Browse

on the panel under the disarming status, then press

【▲】

and

【↓】

to browse set condition of 1-8 defence zone, including defense zone 

type, defence zone places and detector type. Press the key

History

on the 

panel under the disarming status, then press

【▲】

and

【↓】

to browse 40 arming 

/disarming history records,  including event type, time and defence zone 

Содержание YL-007Z

Страница 1: ...red sharp light proof detector brings you more safety Superior program could satisfy various individuation requirements All the arming disarming and alarm memory will be recorded The safety bugs can be inspected in time by the tech of detector self inspection in system Your convenient life comes true once the home appliances are in long distance control by telephone Please read the manual carefull...

Страница 2: ...iance by telephone Long distance arming disarming by telephone and monitoring the sound on spot Could saving 40 arming disarming and alarm records including time defence zone and detector location etc With the patent tech of detector self inspection the panel will lighten the fault indicator light to show the right location and remind of user if it hasn t received the signal from detector within 2...

Страница 3: ...one History Inquiring about info of arming disarming alarm time and defense zone Page Up and Page Down Code For coding detector remote controller and intelligent remote control switch together with setting up user s code Defense Zone Setup For entry into defense zone setup mode Programme For entry into programme mode Arming Away To start up arming away mode Arming Stay To start up arming stay mode...

Страница 4: ...rect light irradiation whenever in the day or night Also it should be kept away from air conditioner and stove etc Its installation height is suggested within 2 to 2 2 meters and its detection angle should be adjusted face to detector zone directly P I R goes to work after 1 minute warm up once turning on the power supply switch notice installation position will cause the alarm veracity 4 Intellig...

Страница 5: ...rd press to confirm entering code status you can key in your code when the figure bar cursor twinkling on the foot of the screen pressing to comfirm It s a 4 digit number please remember it the original password is 1234 4 Settingup Horn The alarm system could decide to use horn or not just up to your demand Press the key program on the panel under the disarming status then press and to twinkle typ...

Страница 6: ...e detector is not suited Every defence zone could accept several detectors Attached detectors have been coded before selling door magnets have been set as the first defense zone stay defence no delay hall The P I R is regarded as the second defence zone out defence zone no delay bedroom 9 Remote Controller Code Press the key program on the panel under the disarming status then press and to twinkle...

Страница 7: ...press to disarm Current status will display on the screen at the same time Notice All the defence zones will take effect under Out status the mode is suitable for nobody in Part of the defence zones take effect under Home status the mode is suitable for anybody in Remote Controller Arming Disarming Press the key Lock on the remote controller the system will enter away disarming status about 20 60 ...

Страница 8: ...umber and serial number 1 4 correspond 1 4 remote control switch The intelligent remote control switch will change its status between turning on and turning off You should hang up and go into remote control system again if you want to change its status Intelligent remote control switch panel itself could operates switch by manual work System Main Tech Parameter Main Panel Power Supply AC 220V 10 D...

Страница 9: ...stance 5 8m Detective View Level 110 Vertical 60 Anti Puppy Jamming Rodent animal bulk Φ30 50mm Sharp White light Resistence 20000Lux Working Envrionment Temperature 10 40 Relative Humidity 90 Remote Controller Power Supply DC 12V 8 4 Inside A23 DC 12V dry battery Static Current 11 0 Emission Current 12 15 mA Emission Frequency f 315 0 2 MHz Emission Time T 1 second Emission Distance Without obstr...

Страница 10: ... Standard pile layer 6 Transpotation Condition Standard pile layer 6 Avoid impact during transit other condition are as above After Service We supply user with perfect after service Don t tear open and maintain by yourselves if it doesn t work please contact your local seller Regarding details please refer to attached Guarantee Card ...

Отзывы: