System Installation 

 

1.

 

Main Panel   

Plug the horn into faucet on the back side , telephone line into line-in faucet, 
joint telephone and the panel through line-out faucet, plug the power supply , 
turn on the switch, then done with the installation. Press the key 

Unlock

to 

let panel in disarming status for fear that it alarma when user install door 
magnet and P.I.R. You can hear one beep in gear when the power supply switch 
is turned on. The panel will beep one time every 30 seconds to remind of 
recording alarm message and telephone numbers. Beep will stop once the set is 
over. 

2.

 

Door Magnet 
It will apperceive open -close of door or windows. Fixing magnet and transmit 
box separately on the door and doorcase with double-face sticker. ( suggestion: 
you’d better fix it with screw due to sticker invalidation after long-time use) Pay 
attention to keep the space between transmit box and magnet no more than 
2mm . 

3.

 

P.I.R  
The device could detect human body move within certain range. Fixing it on the 
wall of main passage or important zone and avoiding direct light irradiation 
whenever in the day or night. Also it should be kept away from air conditioner 
and stove, etc. Its installation height is suggested within 2 to 2.2 meters and its 
detection angle should be adjusted face to detector zone directly. P.I.R goes to 
work after 1 minute warm-up once turning on the power supply switch. (notice: 
installation position will cause the alarm veracity) 

4.

 

Intelligent Remote Control Switch 
Tear open the opposite electronic appliance switch panel and fix current panel if 
you want remote control . The current device supply throttle unit for you to 
control daylight lamp, parallel connecting at two ends of the lamp. 

5.

 

Joint Wired Detector 
The main panel has 7 wired detector faucets, the + - terminal are anode and 
cathode of 12V direct current output which loads maximum 200 mA current. 
Connect one end of signal line to anode while the other end to opposite faucet. 
A-G mean 1-7 defense zones. There are no delay for wired defense zone.   

   

System Setup 

 

1.

 

Record Alarm Message 
Under disarming status, press the key

Record

on the back of main panel and 

keep 3 seconds, starting to record toward the panel after hearing one beep . The 
leave word time should be 10 seconds , and the two beeps (a shorter one and a 
longer one) 

Содержание YL-007Z

Страница 1: ...red sharp light proof detector brings you more safety Superior program could satisfy various individuation requirements All the arming disarming and alarm memory will be recorded The safety bugs can be inspected in time by the tech of detector self inspection in system Your convenient life comes true once the home appliances are in long distance control by telephone Please read the manual carefull...

Страница 2: ...iance by telephone Long distance arming disarming by telephone and monitoring the sound on spot Could saving 40 arming disarming and alarm records including time defence zone and detector location etc With the patent tech of detector self inspection the panel will lighten the fault indicator light to show the right location and remind of user if it hasn t received the signal from detector within 2...

Страница 3: ...one History Inquiring about info of arming disarming alarm time and defense zone Page Up and Page Down Code For coding detector remote controller and intelligent remote control switch together with setting up user s code Defense Zone Setup For entry into defense zone setup mode Programme For entry into programme mode Arming Away To start up arming away mode Arming Stay To start up arming stay mode...

Страница 4: ...rect light irradiation whenever in the day or night Also it should be kept away from air conditioner and stove etc Its installation height is suggested within 2 to 2 2 meters and its detection angle should be adjusted face to detector zone directly P I R goes to work after 1 minute warm up once turning on the power supply switch notice installation position will cause the alarm veracity 4 Intellig...

Страница 5: ...rd press to confirm entering code status you can key in your code when the figure bar cursor twinkling on the foot of the screen pressing to comfirm It s a 4 digit number please remember it the original password is 1234 4 Settingup Horn The alarm system could decide to use horn or not just up to your demand Press the key program on the panel under the disarming status then press and to twinkle typ...

Страница 6: ...e detector is not suited Every defence zone could accept several detectors Attached detectors have been coded before selling door magnets have been set as the first defense zone stay defence no delay hall The P I R is regarded as the second defence zone out defence zone no delay bedroom 9 Remote Controller Code Press the key program on the panel under the disarming status then press and to twinkle...

Страница 7: ...press to disarm Current status will display on the screen at the same time Notice All the defence zones will take effect under Out status the mode is suitable for nobody in Part of the defence zones take effect under Home status the mode is suitable for anybody in Remote Controller Arming Disarming Press the key Lock on the remote controller the system will enter away disarming status about 20 60 ...

Страница 8: ...umber and serial number 1 4 correspond 1 4 remote control switch The intelligent remote control switch will change its status between turning on and turning off You should hang up and go into remote control system again if you want to change its status Intelligent remote control switch panel itself could operates switch by manual work System Main Tech Parameter Main Panel Power Supply AC 220V 10 D...

Страница 9: ...stance 5 8m Detective View Level 110 Vertical 60 Anti Puppy Jamming Rodent animal bulk Φ30 50mm Sharp White light Resistence 20000Lux Working Envrionment Temperature 10 40 Relative Humidity 90 Remote Controller Power Supply DC 12V 8 4 Inside A23 DC 12V dry battery Static Current 11 0 Emission Current 12 15 mA Emission Frequency f 315 0 2 MHz Emission Time T 1 second Emission Distance Without obstr...

Страница 10: ... Standard pile layer 6 Transpotation Condition Standard pile layer 6 Avoid impact during transit other condition are as above After Service We supply user with perfect after service Don t tear open and maintain by yourselves if it doesn t work please contact your local seller Regarding details please refer to attached Guarantee Card ...

Отзывы: