![Wohler VIS 240 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/wohler/vis-240/vis-240_operating-manual_991410040.webp)
Component explanation
40
Functions of the ON-/OFF-key
Press
Functions
2 seconds
System ON/OFF
shortly
Escape (play mode)
shortly
Reset digital meter
counter
3.3
Monitor
3.3.1
Adjusting the Color
Monitor
VIS 2xx / VIS 3xx
Fig. 8: Monitor
With the keys
▼☼▲
the brightness can be adjusted.
▼:
darker
▲:
brighter
With the keys
▼
▲
the color intensity can be
adjusted
▼:
decreasing color intensity up to black and white
▲:
increasing color intensity
3.3.2 Transition from 16:9 Screen to 4:3 Screen
If the monitor has the serial number 11010001, the screen format can be changed from
16:9 to 4:3 or vice versa. You will find the serial number on the back side of the monitor.
•
Switch off the camera system.
•
Press the left monitor key and the on/off-key of
the monitor at the same time.
The screen format has now changed from 4:3 to
16:9 or vice versa.
NOTE!
When inspecting tubes the 4:3 screen is recom-
mended, because the widescreen 16:9 may distort
the image.