Operating manual
Page 8 of 32
B0102
GMI / GML / SAB / GOI
3. Product description
3.1
Purpose of use
The unit GMI, SAB and GOI is designed for the delivery of lube oils as of
10 mm²/s exclusively.
The delivery pump GML-A is designed for the delivery of lube greases up
to NLGI class 2 exclusively.
3.2
Limits of use
The application area of the pump unit’s components is restricted as follows:
Temperature range:
-10
… +50 °C
Depending on the version, these limits of use may be restricted further. Such further
restrictions are dealth with in this operation manual later on.
Besides, the unit’s area of application is determined by the medium to be delivered. Hence,
when determining the area of application, you also need to refer to the technical data sheets
for the medium to be used.
3.3
Ambient conditions
Unit operation in an aggressive atmosphere (solvent vapours, acids,
lyes, salt water mist, etc.) may cause damage to or corrosion of
components and, thus, failure of the system and endangerment due to
leaking lubricant!
Ambient temperature range
Lower temperature limit:
-10 °C
Upper temperature limit:
+50 °C
Relative humidity:
70% at max.
Noise level :
<70 dB(A)
Physical environment
In heights as of 1.000 metres above sea level, the system should be operated after
consultation with the manufacturer only.