Operating manual
Page 14 of 32
B0102
GMI / GML / SAB / GOI
Electric magnet:
Rated power
Variant "A"
30 W
Variant "C"
165 W
Switch-on duration
Variant "A"
100%
Variant "C"
15%
Current at 24 VDC
Variant "A"
1,27 A
Current at 230 VAC
Variant "A"
0,15 A
Variant "C"
0,59 A
Protection type
DIN EN 60529 IP65
Insulation class
F
Plug-in connection
DIN EN 175301-803, shape A
Level switch:
Switching power
10 W / 30 VA
Switching current
max. 0,5 A
Switching voltage
max. 230 VUC
Protection type
DIN EN 60529 IP65
Plug-in connection
DIN EN 175301-803, shape A
Function control:
Voltage
10
… 30 VDC
Load current
≤200 mA
Protection type
DIN EN 60529 IP67
Connection
Plug-in connection M8x1, 3-pin
Output
PNP NO function
When connecting inductive or capacitive loads, the relevant sup-
pressor circuits (diode, RC element, varistor) need to be provided for!
4. Functional description
4.1
Drive
The unit is driven by a d.c. solenoid actuator, which is laterally screwed on the pump casing.
The solenoid actuator is energised by externally switching the voltage supply. For that
purpose, an external controller is required.