Operation manual GMK-A
Page 22 of 35
B0887
6.5.1.3 Assembly of the reservoir types 04 and 05
Assembly of reservoirs 04 and 05 by means of two cylinder screws supplied.
Make sure that the O-ring for sealing the reservoir is located in the sinking.
6.5.1.4 Closing an outlet
1. Remove any existing lubricant lines.
2. Unscrew the non-return valve cartridge using an open-ended or ring spanner SW12.
Note: A possibly screwed-in push-in fitting can remain in the non-return valve car-
tridge and does not have to be removed beforehand.