Service
15
2.4
Pressure reducer setting
The pressure gage can be used to check and adjust the output pressure of the pressure reducer. The auxiliary nipple is screwed in at the descaling connection and
connected to the pressure gage
Check the pressure reducer setting:
-
Start the Service routine “Set pressure reducer”
-
Remove the descaler coupling and install the auxiliary nipple with the pressure gage.
-
Start the service routine and where applicable, set the pressure reducer to 1.8 bar
-
End the service routine, remove the test fitting and reinstall the descaler coupling
Test tool comprising:
Pressure gage 3327300000
Auxiliary nipple 3323208000
O-ring 3303985000