Table 3-25
“DI” Instruction
Parameter
Instruction
Enable
Enable DI. Port1 is for I/O1 and Port2 is I/O2. Both I/O1 and I/O2 are
DI ports
Mode
Selected from OFF, ON and EVENT_COUNTER modes.
OFF Mode: When I/O connects to GND, it will trigger alarm.
ON Mode: When I/O does not connect to GND, it will trigger alarm.
EVENT_COUNTER Model: Enter EVENT_COUNTER mode.
Filter
Software filtering is used to control switch bounces. Input
(1~100)*100ms.
Under OFF and ON modes, WL-G510 detects pulse signal and
compares with first pulse shape and last pulse shape. If both are the
same level, WL-G510 will trigger alarm.
Under EVENT_COUNTER mode, if first pulse shape and last pulse
shape are not the same level, WL-G510 will trigger alarm according
to Counter Action setting.
Counter Trigger Available when DI under Event Counter mode
Input from 0 to 100. (0=will not trigger alarm)
It will trigger alarm when counter reaches this value. After triggering
alarm, DI will keep counting but no trigger alarm again.
Counter Period
It’s a reachable IP address. Once the ICMP check is failed, GRE will
be established again.
Counter
Recover
it will re-count after counter trigger alarm. The value is 0~30000(*100ms).
0 means no counter.
Counter Action
HI_TO_LO and LO_TO_HI is available when DI under Event
Counter mode.
In Event Counter mode, the channel accepts limit or proximity
Содержание WL-G510 Series
Страница 54: ...WL G510 Series Router User Manual 54 Figure 3 35 Trace GUI End...
Страница 60: ...WL G510 Series Router User Manual 60 End...
Страница 62: ...WL G510 Series Router User Manual 62...
Страница 63: ...WL G510 Series Router User Manual 63 3 OpenVPN Client Config Demo...
Страница 64: ...WL G510 Series Router User Manual 64...
Страница 65: ...WL G510 Series Router User Manual 65...