background image

 

 

3. Connection 

3.1 Electric connection: 

1.

 

The lift operates on AC220V-240V, 50Hz, 1 ph. current. 

2.

 

Junction box is a white box located under the lift top plate. 

3.

 

Change the EU plug to your local standard if necessary. All wiring should comply with local and 
national electrical codes and should be done by a licensed electrician. 

4.

 

All operating switches should be “off” before power connection. 

5.

 

Put the plug into the power outlet 

Caution: Before operating the first time, make sure that nobody is standing under the projector lift. Adjust bottom limit switch 
so that nobody gets injured during operation. See next chapter on how to adjust the limit switches. 

 

3.2 Limit switch adjustment: 

The automatic stop positions (the positions where the lift stops when extending and where it stops when 
retracting) can be adjusted as required. These are preset and for most situations, 
the switches should not need adjustment. 
To adjust the switches, use the equipped 

allen key

. The adjustment sockets are 

located at the left side under the lift top plate (viewing from the front); 
The yellow hole is for adjusting upper limit. Clockwise movement will reduce upper 
limit and anticlockwise movement is for increasing upper limit. 
The white hole is for adjusting down limit. Clockwise movement will reduce down 
limit and anticlockwise movement is for increasing down limit. 

Caution: Rated motor continuous operation time is 4 minutes. Excessive operation may cause 
the motor to overheating and will stop running due to a protective function. When this 
occurs, please stop for 15 minutes to wait the motor to cool down and then star operation 
again. 

Содержание PL180L

Страница 1: ...y mount solutions for audio video installations Motor Lift hanger Lift top plate Running belt Stabilizing aluminum scissor Screw pole Capacitor Junction box Lift top plate Projector Lift bottom plate Universal projector bracket optional Elegant ceiling closure Local control buttons Remote control ...

Страница 2: ...have doubts about the safety of the installation contact Wize AV Customer Service or call a qualified contractor Wize AV is not liable for damage or injury caused by incorrect mounting assembly or use The hardware provided with this product is exclusively intended for installation on surfaces made of solid wood or concrete with a maximum of 16 mm of drywall For surfaces made of other materials for...

Страница 3: ...eiling closure panel installation 5 2 4 Projector installation 5 3 Connection 6 3 1 Electric connection 6 3 2 Limit switch adjustment 6 4 Drawings 7 4 1 PL180L PL300 ceiling closure panel 7 4 2 PL180L PL300 closure frame 8 4 3 PL180L PL300 bottom plate 9 5 Warranty 10 6 CE Declaration of conformity 11 ...

Страница 4: ...AxBxC cm 700х508х220 700x508x280 Lift height closed cm 22 29 Lift height fully extended cm 180 300 Travelling distance cm 158 372 Net weight kg 25 29 5 Lift packing dimensions cm 995x725x460 995x725x520 Running speed 45 mm sec Rated operation time 4 min Input AC220V 0 83A 191W ...

Страница 5: ...ceiling opening 5 Choose proper wire for the projector and start wire routing Caution 1 Must hang suspend the lift before power on Lift must be able to drop down by gravity Running without suspension will damage the parts inside and might hurt installer 2 The installation must be done by two or more professional technicians 3 Make sure the ceiling is strong Lift must be installed on a reinforced l...

Страница 6: ...ips The height between the ceiling and the ceiling closure is adjustable by adjusting the position of the screw nuts 2 4 Projector installation 1 Choose proper projector bracket Install the projector with the bracket tighten the screws 2 Hook the projector bracket on the bracket hook Refer to the drawings below 3 Wiring connection Bind all the wires in Z shape along the scissors fix the wires on t...

Страница 7: ...ns the positions where the lift stops when extending and where it stops when retracting can be adjusted as required These are preset and for most situations the switches should not need adjustment To adjust the switches use the equipped allen key The adjustment sockets are located at the left side under the lift top plate viewing from the front The yellow hole is for adjusting upper limit Clockwis...

Страница 8: ...7 4 Drawings 4 1 PL180L PL300 ceiling closure panel all measurements are in mm ...

Страница 9: ...8 4 2 PL180L PL300 closure frame all measurements are in mm ...

Страница 10: ...9 4 3 PL180L PL300 bottom plate all measurements are in mm ...

Страница 11: ...ations improper installations or installations over the specified weight range To the maximum extent permitted by law Wize AV disclaims any other warranties expressed or implied including warranties of fitness for a particular purpose and warranties of merchantability Wize AV will not be liable for any damages arising out of the use of or inability to use Wize AV products Wize AV bears no responsi...

Страница 12: ...ctive LVD Human exposure to Electromagnetic fields EMF up to 300 GHz EN 60335 1 2012 Electrical appliances Safety Part 1 General requirements EN 60335 2 56 2003 A1 2008 Electrical appliances Safety Particular requirements for projectors and similar appliances Certification is performed by Anbotek product safety under Registration no AT1311797S Report no 201311857S In accordance to EU regulations a...

Отзывы: