background image

WITURA

 

TECHNOLOGY

 

SDN

 

BHD

 

|

                                

WT

1672B

 

GSM

 

Wireless

 

Alarm

 

System

 

User

 

Manual

 

V2.0

9

 

18

 

Call

 

alert

 

to

 

Admin

 

Number

 

when

 

turn

 

on

 

/

 

off

 

the

 

alarm

 

equipment

 

*25*N#

 

When

 

Setting

 

as

 

*25*5#

 

Call

 

switch:

 

wireless

 

alarm

 

 

2013

10

10

 

17:18

 

Thu

 

N=0

 

means

 

switch

 

off

 

all

 

alarm

 

alert,

 

which

 

means

 

any

 

alarm

 

alert

 

from

 

the

 

equipment,

 

it

 

will

 

not

 

call

 

admin

 

number

N=1

 

means

 

when

 

the

 

equipment

 

is

 

switch

 

on,

 

it

 

will

 

call

 

admin

 

number

 

N=2

 

means

 

when

 

the

 

equipment

 

is

 

power

 

outage,

 

it

 

will

 

call

 

admin

 

number

N=3

 

means

 

when

 

the

 

equipment

 

is

 

line

 

cut

 

trigger,

 

it

 

will

 

call

 

admin

 

number

N=5

 

means

 

when

 

the

 

9

 

channel

 

wireless

 

alarm

 

having

 

the

 

alarm

 

alert,

 

it

 

will

 

call

 

admin

 

number

 

N=7

 

means

 

1

6

 

,

 

it

 

will

 

call

 

admin

 

number

 

If

 

there

 

is

 

a

 

repeat

 

setting,

 

it

 

will

 

overwrite

 

the

 

before

 

setting

 

and

 

take

 

the

 

last

 

setting.

 

Factory

 

Default

 

as

 

N=0

 

which

 

means

 

any

 

alarm

 

alert

 

from

 

the

 

equipment,

 

it

 

will

 

not

 

call

 

admin

 

number

 

19

 

Edit

 

Input

 

Messages

 

for

 

the

 

system

 

and

 

9

 

Channels

 

Wireless

 

Alarm

 

Alert

 

Messages

 

*26*NN*XXXXXXXX#

 

When

 

Setting

 

as

 

*26*00*The

 

equipment

 

has

 

already

 

started!#

 

Startup

 

user

 

defined

 

information:

 

The

 

equipment

 

has

 

already

 

started!

  

 

2013

10

10

 

17:24

 

Thu

 

 

When

 

Setting

 

as

 

*26*01*The

 

door

 

closed!#

 

Wireless

 

1

 

defined

 

information:

 

The

 

door

 

closed!

  

 

2013

10

10

 

17:21

 

Thu

 

NN

 

=00

 

means

 

Edit

 

for

 

Input

 

Alert

 

Message

 

for

 

system

 

startup

 

 

NN

 

=01~09

 

means

 

Edit

 

for

 

Input

 

Alert

 

Message

 

for

 

which

 

channel

 

of

 

Wireless

 

Alarm

 

Equipment

 

that

 

connected

 

 

NN

 

=10

 

means

 

Edit

 

for

 

Input

 

Alert

 

Message

 

for

 

line

 

cut

 

alert

 

XXXXXXX

 

is

 

the

 

text

 

messages

 

content

 

which

 

can

 

up

 

to

 

70

 

alphabet.

 

When

 

the

 

text

 

message

 

content

 

successfully

 

programmed,

 

it

 

will

 

overwrite

 

the

 

system

 

default

 

text

 

messages

 

Содержание WT-1672B

Страница 1: ...WITURA TECHNOLOGY SDN BHD WT 1672B GSM Wireless Alarm System User Manual V2 0 1 WT 1672B GSM Wireless Alarm System USER MANUAL VERSION 1 2 UPDATED AUG 2013...

Страница 2: ...nents like contacts motion sensors remote control and more of these include GSM modules which allow the system to interact with a home owner s mobile device by sending a text message or call to the ow...

Страница 3: ...to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185300 your phone number 2 3 4...

Страница 4: ...he button FACTORY at the mother board until you hear the du This means the unit back to the factory default This means you already reset the unit to factory default Now you can start to call again to...

Страница 5: ...the factory password to your new password Enter the factory password follow by your new password 3 Add telephone number into the admin list 1 1 telephone number For example set Admin number 1861718530...

Страница 6: ...l CSQ 25 32 Signal Excellent System working well 8 Checking the list of Wireless Alarm that already added to the system 6 Equipment 1 73c704 2 73c708 3 73c702 4 73c701 5 6 7 8 9 2013 10 10 16 14 Thu C...

Страница 7: ...you want to activate the alarm function just enter 10 1 When Deactivate Alarm Function is equal to using the Remote Control to disarm The D7 Green LED light in the system will turn off All the functio...

Страница 8: ...m to text you for any acknowledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost 16 Security mode Open Mo...

Страница 9: ...ng it will overwrite the before setting and take the last setting Factory Default as N 0 which means any alarm alert from the equipment it will not call admin number 19 Edit Input Messages for the sys...

Страница 10: ...ll return a SMS with Blank Message 21 Delete input messages programmed in the system and the 9 channels wireless alarm alert messages 28 NN When Setting as 28 00 Delete OK 2013 10 10 17 42 Thu After d...

Страница 11: ...ich means successful pairing the remote control with the system If Admin Numbers been programmed all the admin number will receive the SMS Message of the Pairing Remote Control location When hear 3 TI...

Страница 12: ...ED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is r...

Страница 13: ...uction Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 2amps GSM Frequency MHz GSM900 1800Mhz or GSM850 900 1800 1900Mhz Humidity Less Than 8...

Страница 14: ...e PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN nu...

Страница 15: ...es when program the administrators number Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled 4 I am not receiving any text messages when...

Страница 16: ...n ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper app...

Отзывы: