background image

WITURA

 

TECHNOLOGY

 

SDN

 

BHD

 

|

                         

WT

1672A GSM

 

Power

 

Outage

 

Alarm User

 

Manual

 

V1.8

 

3

 

SETTING

 

UP

 

AND

 

PROGRAMMING

  

 

When

 

first

 

booting

 

up

 

the

 

system

 

you

 

will

 

see

 

Green

 

LED

 

Lights

 

on

 

the

 

side

 

of

 

the

 

Enclosure

 

and

 

it

 

should

 

light

 

up

 

when

 

the

 

Network

 

is

 

applied

 

to

 

the

 

unit.

 

 

The

 

Green

 

LED

 

is

 

the

 

network

 

Indicator

 

and

 

this

 

will

 

light

 

up

 

when

 

attempting

 

to

 

log

 

on

 

to

 

the

 

network

 

flash

 

inconsistently

 

until

 

it

 

locates

 

the

 

network.

 

 

A

 

Phone

 

Call

 

to

 

the

 

SIM

 

Card

 

Number

 

will

 

now

 

Latch

 

the

 

Relay

 

permanently

 

ON

 

and

 

Switch

 

the

 

device

 

being

 

Controlled

 

On.

 

 

The

 

Status

 

of

 

the

 

Relay

 

will

 

remain

 

as

 

on,

 

until

 

the

 

unit

 

receives

 

a

 

second

 

Call

 

to

 

the

 

Unit

 

of

 

which

 

will

 

now

 

Latch

 

the

 

Relay

 

Permanently

 

off.

 

 

Both

 

Calls

 

used

 

to

 

Latch

 

the

 

Relay

 

either

 

on

 

or

 

off

 

are

 

automatically

 

disconnected,

 

once

 

the

 

relays

 

are

 

activated

 

and

 

never

 

incur

 

any

 

Network

 

Call

 

Costs.

 

 

Beside

 

calls

 

to

 

switch

 

off

 

or

 

on,

 

the

 

unit

 

also

 

can

 

be

 

permanently

 

switch

 

off

 

and

 

on

 

by

 

sending

 

the

 

unit

 

a

 

text

 

message

 

command

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание WT-1672A

Страница 1: ...WITURA TECHNOLOGY SDN BHD WT 1672A GSM Power Outage Alarm User Manual V1 8 1 WT 1672A GSM Power Outage Alarm USER MANUAL VERSION 1 2 UPDATED AUG 2013...

Страница 2: ...to switch on the generator backup battery and etc The GSM Remote Control system supports timer function the user can set schedule to turn on off the switch For example put your pump motor on a schedu...

Страница 3: ...stently until it locates the network A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on unt...

Страница 4: ...the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185299 your phone number 2 3 4 5...

Страница 5: ...t back to the factory default This means you already reset the unit to factory default Now you can start to call again to set the administrator This method of setting is only allowed to set 1 administ...

Страница 6: ...he factory password to your new password Enter the factory password follow by your new password 3 Add telephone number into the admin list 1 1 telephone number For example set Admin number 18617185300...

Страница 7: ...larm Function 10 N When Sending 10 0 Alarm switch OFF 2013 10 10 16 28 Thu N 0 Deactivate Alarm Function N 1 Activate Alarm Function Factory Default Setting as N 1 For example if you want to activate...

Страница 8: ...time is up Master relay OFF 2013 10 10 16 33 Thu Note if the system is only ON after the scheduled time the unit will still running accordingly System startup Master Replay OFF 2013 10 10 16 33 Thu N...

Страница 9: ...0 Thu When sending command 22 1 Status switch ON 2013 10 10 17 08 Thu N 1 means after make the phone call to the system it will return the SMS for the status to the caller N 0 means after make the pho...

Страница 10: ...N 1 means switch on the relay by SMS Message N 0 means switch off the relay by SMS Message 18 Turn on off the administrative call 25 N 0 Call Switch OFF 1 Call Switch Start Up Alarm 2 Call Switch AC d...

Страница 11: ...ect the cable to terminals 110V 220V N ensuring positive is connected to terminal 110v 200V switch on the power supply the red power LED will light indicating power is present the blue network LED ind...

Страница 12: ...d person Connector 1 2 3 4 5 6 Board Label J3 Power Supply Description Relay Power Supply 1 Connection Details NC No COM E N L Note 1 The Relay J3 Was using for turning on and off the electrical appli...

Страница 13: ...has been activated and that the PIN request has been disabled If the unit is in a low signal strength area consider using an external GSM antenna or changing to another network provider 3 I am not rec...

Страница 14: ...workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and impro...

Отзывы: