25
WT-1011RC IP65 GSM Remote Controller And Alarm System
WT-1011RC IP65 – USER MANUAL – Rev.1.6 – Technical Support:
COPYRIGHT ©2010 WITURA CORPORATION SDN BHD
To reset the total counter value, you can send the following SMS message to the unit.
Text Command:
*CLA[N]#
N stands for Input number 1 – 2
Example:
When *CLA1# is sent, means the total increment counter value will be reset
The system has the function to activate the relay for a specific time and then be
deactivated for a specific time in a repeating process. To set the opening & closing time
of the relays, you can send the following SMS command to the unit.
Note: This function
only applied in (F2) selectable input function 5 and 6
.
This function will be disabled under GPRS
Mode.
Text Command for Opening time:
*PWT2#XXXXX
XXXXX stands for 5 digits value: The number of seconds
Text Command for Closing time:
*PWK2#XXXXX
XXXXX stands for 5 digits value: The number of seconds
Example:
Opening time of output 2 is set as 1 minute (*PWT2#00060) and the Closing time as 5
seconds (*PWK2#00005) and function 5 is applied on Input 2. When input 2 triggered,
output relay 2 will be activated for 1 minute and close for 5 seconds and then back on
for 1 minute and close again for 5 seconds and will keep on repeating the process until
the command *RLY2#00000 is issued.
5.7.7 Reset the Total Increment Counter Value
5.7.8
Setting the Function of Opening & Closing time for Output Relay