background image

-------------------------  

  -------------------------

 

 

 

Installation Sheet

 

Page PM.9.002886.EN.004

 

 

WSE 81 PLUS and WSE EVO 

Date 

08.02.2016 

 

P/No: 

500 852GB/Version 1 

 

 

 

 

 

 

 

 

 
 

 

Technical Specification 

 

WLS Power Supply 1001004A01 

Input Voltage 

115-240V AC 

Output Voltage 

24V DC nominal 

Output Current 

120mA (see compatible detectors) 

Compatible Detectors 

WSE 81 PLUS, WSE EVO PLUS 

Compatible Detectors logic output 

PNP N/C 
PNP N/O 
NPN N/C 
NPN N/O 

Trigger Logic Settings 

Two logic output switches (SW2 and SW3 to be set for detector configuration) 

Relay Output 

Single pole changeover with hard silver contacts.  Maximum switching current 5 amps at 240V AC 

Housing 

High impact strength plastic box, 130x100x45mm 

Connections 

Screw terminal blocks 

Audible Tone 

Fitted with a beeper and beeper ON/OFF switch 

 

 

 

RX Cable connection

 

WLS  Switch 
Setting

 

0V 

+12V 

TRG 

LNK 

NPN 

N/C 

Green/Black 

Red 

Blue 

Yellow

 

 

 

 

 

     

 

Supply- 

voltage 

 
 
 
 

 

Door Re-open 

circuit 

 

TO LIFT CONTROLLER OR 
DOOR OPEN CIRCUIT 

TX CABLE 

0V - BLACK 
+12V - RED 
 

 

Please note

: The preferred setting of 

the switches is NPN and N/C for 

safety operation 

 

 

 

 

 

COM 

 

N/C 

 

N/O 

 

Содержание WSE 81 PLUS Series

Страница 1: ...xcerpts needs the written Authorization of the WITTUR Austria Ltd We reserve the right to make alterations with respect to the specifications and figures in this manual INSTALLATION The systems can be installed either on the moving doors or statically in a position on the end of the door sill a Dynamic Installation The system is mounted on the car doors using the dynamic fixing kit provided 1 Posi...

Страница 2: ...eed 42V DC under any circumstances Peak ripple voltage should not exceed 42V and average voltage not exceeds 42V Sufficient power the supply must be capable of supplying at 100mA plus whatever current is needed to drive the door re open circuit on the lift Note if you have any doubts then you should use a WLS power supply IMPORTANT 1 Do not shorten cables by cutting them 2 Ensure that all cables a...

Страница 3: ...00 852GB Version 1 Figure 3 Connection diagramm ECO MIDI SUPRA door controller If you are using the WLS power supply unit PLEASE USE TAPE FOR INSULATING THE GREEN WIRE TO AVOID A SHORT CIRCUIT IN THE WLS POWERSUPPLY UNIT X16 X15 Transmitter A Receiver B yellow red blue black black red green ...

Страница 4: ...utput switches SW2 and SW3 to be set for detector configuration Relay Output Single pole changeover with hard silver contacts Maximum switching current 5 amps at 240V AC Housing High impact strength plastic box 130x100x45mm Connections Screw terminal blocks Audible Tone Fitted with a beeper and beeper ON OFF switch RXCableconnection WLS Switch Setting 0V 12V TRG LNK NPN N C Green Black Red Blue Ye...

Страница 5: ...paque tape is removed When the 20 second timeout has completed the detector will switch back to normal mode so at the next power cycle it will not go into learning mode but it will remember those beams which need to be disabled To re enable learning mode the detector must be switched on with ALL the beams including previously disabled beams unobstructed To prevent the detector from having the lear...

Страница 6: ...0mm Supply voltage 11 42 V DC continuous max 100 mA max peak 44V 11 42 V DC continuous max 100mA max peak 44V Output signal N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm N C or N O Voltage free relay contact V Max 45VAC current Max 0 35A Max ON Resistance 2 Ohm Diagnostic LED 1 red LED in receiver detector RX visible through lens 1 red LED in receiver ...

Отзывы: