Installation Sheet
Page PM.9.002886.EN.004
WSE 81 PLUS and WSE EVO
Date
08.02.2016
P/No:
500 852GB/Version 1
Technical Specification
WLS Power Supply 1001004A01
Input Voltage
115-240V AC
Output Voltage
24V DC nominal
Output Current
120mA (see compatible detectors)
Compatible Detectors
WSE 81 PLUS, WSE EVO PLUS
Compatible Detectors logic output
PNP N/C
PNP N/O
NPN N/C
NPN N/O
Trigger Logic Settings
Two logic output switches (SW2 and SW3 to be set for detector configuration)
Relay Output
Single pole changeover with hard silver contacts. Maximum switching current 5 amps at 240V AC
Housing
High impact strength plastic box, 130x100x45mm
Connections
Screw terminal blocks
Audible Tone
Fitted with a beeper and beeper ON/OFF switch
RX Cable connection
WLS Switch
Setting
0V
+12V
TRG
LNK
NPN
N/C
Green/Black
Red
Blue
Yellow
Supply-
voltage
Door Re-open
circuit
TO LIFT CONTROLLER OR
DOOR OPEN CIRCUIT
TX CABLE
0V - BLACK
+12V - RED
Please note
: The preferred setting of
the switches is NPN and N/C for
safety operation
L
N
E
COM
N/C
N/O