Changes can be made without notice

 

 

PM.2.004922.EN - 810-000-000 SRS DC-PWM

©

   · Edition 22 July 2020

In order to prevent possible damage to the wiring cables by coming into contact with the drive belt, they are fixed to the header as shown 

in the following image:

Note

: In case of motor replacement be sure to bind the excess cable lenght as above pictured, to avoid any contact of the motor cable with the driving belt.

Warning:

• 

 to avoid possible induced currents within field wiring, it is recommended to shield the Ka and Kc signals (connector pins 3, 5 and 

15) with grounded, shielded cables.

• 

Changes made to the factory wiring length or position can damage the EMC system characteristics and is not recommended.

4.1.1 Detector/Photocell/Barriers: Signal-Only Connection to the Door Controller (Direct Connection)

This connection requires a dry (voltage free) external relay contact connected to the Door Controller Connector pins 15-23.

It is possible to connect the single output signal from a photocell (or similar device) formed by a voltage free contact, so that the door 

controller will directly receive the command to re-open. The photocell (or similar device) has therefore an independent power supply and 

sends only its outgoing signal to the Sematic SRS DC-PWM© controller.

During the reopening of the door the controller sends a signal to the main lift controller through the IM relay contact (green led is on).

4.1.2 Detector/Photocell/Barriers: Complete Connection to the Door Controller

Complete Connection means that the device is powered by, and sends the re-open signs directly to the Sematic SRS DC-PWM© controller. 

The controller then sends a signal to the main lift controller through the IM relays contact (green led is on).

It is possible to have the complete connection of detectors or photocells with a 24 Vdc max 100 mA supply and a PNP N/O output, through 

the connector pins:

33 GND

ground connector pin

32 IN

PNP N/O or N/C signal from

detector/photocell/barrier

31 + 24 Vdc

Vdc power supply to

detector/photocell/barrier

30 NC

dummy free connector pin

 (it can be used as a dummy connector for connection

between the detectors system components).

Содержание sematic SRS DC-PWM

Страница 1: ...ittur com Copyright WITTUR 2020 SRS DC PWM Drive No part of this publication may be reproduced or translated even in part without prior written permission from WITTUR Subject to change without notice...

Страница 2: ......

Страница 3: ...Instruction with handset 15 6 5 Closing Rest type Instruction with handset 16 6 5 1 Motor on default 16 6 5 2 Motor off 16 6 5 3 PM activation Delay Default 300 sec 16 6 5 4 PM Opening space Default...

Страница 4: ...8 5 2 SKATE TYPE select by keypad 23 8 5 4 CLOSING REST TYPE select by keypad 23 8 5 5 MOTOR select by keypad 23 8 5 6 MAX CURRENT END CH select by keypad 23 8 5 7 LA THRESOLD 24 8 6 Maintenance Menu...

Страница 5: ...e disclosed to anyone without Sematic s written consent apart from authorized representatives employed by the user which commits itself to the confidentiality clause The Company that makes use of the...

Страница 6: ...omatic lift doors Frame and frameless glass doors Enhanced car door operator solutions Complete cabins Car Frames Custom integrated packages Special lift doors cabins and car frames ELEVATOR SYSTEMS S...

Страница 7: ...n ensured 1 Quality control of raw material supply 2 Process control 3 Product control 4 Conformity tests according to Sematic specifications Furthermore Sematic guarantees the performance life of its...

Страница 8: ...45 plug The handset 7 is a key pad that allows viewing and modification of the function parameters stored in the controller It is important to use the Sematic handset for installation or maintenance a...

Страница 9: ...DC PWM Edition 22 July 2020 2 1 SPEED PROFILE 9 Opening cycle O1 Opening low speed O2 Opening hight speed Closing cycle C1 Closing low speed C2 Closing hight speed Key Ka Door opening Kc Door closing...

Страница 10: ...60 C HUMIDITY non condensing between 20 and 80 PROTECTION rapid cartridge fuse 5x20 4 A PERFORMANCE SPEED separately adjustable for opening and closing through regulation trimmers REVERSAL SENSITIVIT...

Страница 11: ...om Changes can be made without notice PM 2 004922 EN 810 000 000 SRS DC PWM Edition 22 July 2020 4 SIGNALS TO FROM THE DOOR CONTROLLER 4 1 CONNECTIONS 1 Safety chains 2 Main Lift Controller 3 Photocel...

Страница 12: ...input signal Voltage from the Main Lift Controller range from 6 to 24 V CC To use this feature Remove the link between terminals 37 38 Connect terminal 37 to the external input signals power source 0V...

Страница 13: ...utput signal from a photocell or similar device formed by a voltage free contact so that the door controller will directly receive the command to re open The photocell or similar device has therefore...

Страница 14: ...signal loss or failure of the main lift controller the door controller immediately stops the door movement Note in manual mode the main lift controller signals are not active if CLS or OPN switches ar...

Страница 15: ...of the doors in low speed forced closing by closing the 15 22 connector pins using a relay voltage free contact 6 3 MOTOR ROTATION DURING CLOSING This function fixes the motor rotation during the clo...

Страница 16: ...position error Default 5 mm This sub parameter represents the space threshold with relation to the open skate parking point represented by the PM ACTIVATION DELAY parameter within which the panels can...

Страница 17: ...and waits for external manitenan ce cod 05 5 flashes pause Encoder jerk Interruption of the motor s Encoder cables or interruption of the motor cables after system s start up or the connecting plug t...

Страница 18: ...losing signal is given for instance after power supply interruption it performs a reset cycle i e it searches for a closing limit at low speed not a self learning cycle 7 2 SELF LEARNING CYCLE PROCEDU...

Страница 19: ...speed turn ing it clockwise will set the high closing speed from the minimum speed value to the maximum speed value LW CLS trimmer sets the low closing speed turn ing it clockwise will set the low cl...

Страница 20: ...icture 3 a 16 mm diameter hole is required in any chosen position within the Car walls Note when the handset is connected to the controller the display shows the warrantly expiration date 2 years from...

Страница 21: ...ittur com Changes can be made without notice PM 2 004922 EN 810 000 000 SRS DC PWM Edition 22 July 2020 8 2 USER HANDSET MENUS AND SUBMENUS Closing Rest type Max current end CL LA Threshold Final low...

Страница 22: ...confirm the option On the display the following options are viewed High speed OP XX Low speed OP XX High speed CL XX Low speed CL XX Revers force XX N Acc AP Dec AP Acc CH Acc CH Using keys and to ru...

Страница 23: ...osed skate Open skate Using keys and select the required option and press Ok to confirm Keeping the same values on the screen press OK to confirm the following options PM ritardo attivazione PM apertu...

Страница 24: ...ave been performed in this working time and the manufacture date The following options are available BACK Press key F1 to restore the menu Maintenance MENU Press key F3 to restore the Main Menu If the...

Страница 25: ...available BACK Press key F1 to restore the menu MAINTENANCE MENU Press key F3 to restore the MAIN MENU The access to the MANUFACTURER MENU is reserved protected by password If the option SET FACTORY...

Страница 26: ...between handset and controller during the data transfer turn off the controller turn it on again and reconnect the handset The upload starts again from the beginning 10 DOOR OPERATOR MAINTENANCE At le...

Страница 27: ......

Страница 28: ...YOUR GLOBAL PARTNER FOR COMPONENTS MODULES AND SYSTEMS IN THE ELEVATOR INDUSTRY More information about Wittur Group available on line a WITTUR brand a WITTUR brand a WITTUR brand...

Отзывы: