background image

Änderungen vorbehalten!

Subject to change without notice!

Overspeed Governor
OL35E-NA

Operating instructions

Blatt/

sheet PM.7.002374.022

Datum/

date

08.04.2011

Stand/

version D-20.03.2018

Geprüft/

approved WAT/MZE

5.3.6

Check the function of the overspeed
contact

Turn contact plate by hand so that contact cam
on Overspeed contact is pushed. If controller is in
normal mode you should not be able to drive the
elevator.

5.4 Functional check

5.4.1 Tripping speed (CS / TS):

The tripping speed must be checked by an author-
ized person.

Disconnect the rope clamp from the synchro-
nization.

Rotate  the  governor  manually  in  tripping
direction - Simultaneously measure the speed
on the rope with a speedometer.

Accelerate the rotation speed - as slow as pos-
sible  -  until  the  speed  governor  triggers
mechanical.

•  Compare the measured value with the values

given in the chapter 4.1.

Connect the rope clamp with the synchroniza-
tion lever again after successful testing!

The test must be repeated if the mechani-
cal  tripping  speed  don’t  correspond  with
the values in chapter 4.1.

The resulted figures may not be exactly (up
to  a  few  percent) the  same  as  written  on
the type label, although it is still correct.

Reason:

a) Figure in label is the nominal as ordered (for

tolerances see 4.1).

b) The un-defined acceleration via hand possibly

cause different measuring results.
(The acceleration should be as less as possible,
~0.10m/s²)

5.4.2

Brake force (lifting force) of the
OL35E-NA governor

*

governor force must be 67% greater than safety

gear activation force, according ASME A17.1

Influences what will reduce the brake force:

a) Lubrication inside the brake
b) Worn  out  of  the  breaklining  (see  lifetime  of

the brake)

c) Damaged or broken plate spring

Lifetime of the brake:

a) Maximum 250 turns with maximum 15 turns

per test

b) If more than 10 turns per test, the brake of the

governor must cool off for 30 minutes mini-
mum.

Contact plate

Overspeed contact

Max lifting force*

300N

480N

Allowed brake force    500N - 1000N    800N- 1300N

OL35E-NA

D

D

Содержание OL35E-NA

Страница 1: ...Original Instruction No part of this publication may be reproduced or translated even in part without prior written permission from WITTUR Subject to change without notice Product manufacturer referen...

Страница 2: ...he encoder PM 7 002374 014 3 6 2 Wiring assignment PM 7 002374 014 3 7 Attaching the safety cover PM 7 002374 015 4 Function testing PM 7 002374 016 4 1 Standard speed settings PM 7 002374 018 5 Maint...

Страница 3: ...heels 3 connected with the flyweights move towards the trip wheel 6 in the centre If the nominal elevator speed is exceeded the fly weight 1 will hit the contact plate 7 activating the overspeed conta...

Страница 4: ...pany nor consists of original WITTUR spare parts 1 3 Safety precautions WITTUR machine installation or repair engineers are chiefly responsible for the safe operation of machinery It is essential to c...

Страница 5: ...t the factory and order number correspond that the details on the name plate correspond to those on the order the elevator speed the elevator travel height the rope wheel diameter suites to the over s...

Страница 6: ...PM 7 002374 005 Datum date 08 04 2011 Stand version 22 03 2013 Gepr ft approved WAT MZE Geschwindigkeitsbegrenzer OL35 Betriebsanleitung Geschwindigkeitsbegrenzer OL35 D7A0MDE 03 2009 WITTUR GmbH Sowi...

Страница 7: ...overspeed governor is pre adjusted and calibrated at the factory No re adjust ment is allowed 2 Name plate designation identification Date of manufacture Type term Type term Serial number Nominal spe...

Страница 8: ...This might reduce the governor breaking force nderungen vorbehalten Subject to change without notice Overspeed Governor OL35E NA Operating instructions 3 Installation Blatt sheet PM 7 002374 007 Datu...

Страница 9: ...nces The overspeed governor must be installed vertically The overspeed governor must be installed in a way that the governor rope runs par allel into the wheel groove The max allowed tolerances are ma...

Страница 10: ...pay attention to the overspeed governor rotational direction during each stage of installation 1 If a supporting base is being used it must be screwed to the overspeed governor 2 Position the overspe...

Страница 11: ...nd to the rope socket and attach it to the safety gear 3 Install the tension weight refer to operating instructions of tension weight 4 Connect the second rope end to the rope sock et of the safety ge...

Страница 12: ...t use category AC 15 B300 Ue Ie 240V 1 5A thermal current Ithe 5A insulation voltage Ui 250V AC protection type IP 43 approved in accordance VDE 0660 T100 IEC EN 60947 5 1 1 2 3 4 Overspeed contact Wo...

Страница 13: ...ac tory Power supply of the motor Voltage 24VDC 10 15 Current 1 6A 10 switch on time min 2 sec max 30 sec Motor protection The motor protection PTC is included in the con nection box of the remote con...

Страница 14: ...L35E NA Operating instructions Blatt sheet PM 7 002374 013 Datum date 08 04 2011 Stand version D 20 03 2018 Gepr ft approved WAT MZE pin 7 8 24 VDC GND GND 24 VDC Motor Position B left trip mechanical...

Страница 15: ...th 4 ft cable protected by a flexible conduit 3 6 1 Specification of the magnet sensor 3 6 2 Wiring assignment nderungen vorbehalten Subject to change without notice Overspeed Governor OL35E NA Operat...

Страница 16: ...Governor OL35E NA Operating instructions Blatt sheet PM 7 002374 015 Datum date 08 04 2011 Stand version 22 03 2013 Gepr ft approved WAT MZE 3 7 Attaching the safety cover Move the delivered covering...

Страница 17: ...run Risk of crushing injuries The entire elevator travel path should be slowly travelled in inspection mode before the functions tests Attention should be paid to the clearance of all fastened parts e...

Страница 18: ...t be exactly up to a few percent the same as on the type label although it is still correct Reason a Figure in label is the nominal as ordered for tolerances see 4 1 b The un defined acceleration via...

Страница 19: ...8 8 3 14 Contact speed CSup ft min m s min max 367 5 1 87 367 5 1 87 525 0 2 67 525 0 2 67 452 0 2 30 497 2 2 53 625 0 3 18 687 5 3 49 nderungen vorbehalten Subject to change without notice Overspeed...

Страница 20: ...diately taken out of use should any damage or irregularities arise which could possibly impair operational safety The checks and tests mentioned below are the minimum required checks to ensure product...

Страница 21: ...te any part of the governor or the governor rope 5 3 1 General checkings Check the overspeed governor and belonging components for damages and deformation Check the fixing of the overspeed governor 5...

Страница 22: ...be replaced Keep the governor clean especially the flyweight springs because they are mainly responsible for proper operation and correct tripping 5 3 5 Check the condition of the wheel bearing Check...

Страница 23: ...roniza tion lever again after successful testing The test must be repeated if the mechani cal tripping speed don t correspond with the values in chapter 4 1 The resulted figures may not be exactly up...

Страница 24: ...e going in contact with the trip wheel shown at mark B d Pull down the force gauge in the tripping direction as long as the governor pulley or and the governor rope starts to move e The shown value mu...

Страница 25: ...peration without a over speed governor even for short periods of time is forbidden The following repairs should be carried out on site by qualified fitters service personnel Tensioning the governor ro...

Страница 26: ...Beschreibung der nderung C CRW 7572 20 09 2017 some minor changes D CRW 8407 20 03 2018 Wiring picture changed table added text changed Overspeed Governor OL35E NA Operating instructions Blatt sheet P...

Страница 27: ...9 Dresden Germany GERMANY WITTUR S R O Priemyseln ulica 2747 7 963 01 Krupina Slovakia SLOVAKIA WITTUR Elevator Components India Pvt Ltd Survey nos 45 1B 3 4 Pondur Village Sriperumbudur 602 105 Tamil...

Отзывы: