Electrical System
49
Packer Fully Extended Proximity Switch
This proximity switch stops the packer when it reaches its fully extended position (pack cycle).
Figure 5
-
9 Packer Fully Extended proximity switch
Location
The Packer Fully Extended proximity switch is mounted on the front wall of the body, on the street
side.
I
MPORTANT
:
This procedure must be performed by 2 people.
Testing procedure:
1.
Empty all refuse from the body.
2.
Initiate a pack cycle and observe the fully extended position of the packer.
3.
Adjust the Packer Fully Extended proximity switch if:
• The packer stops before or after reaching the fully extended position (see illustration below).
Adjustment procedure:
1.
Move the packer so that the packer blade is at 4 inches in front of the mid-body breaker bar.