background image

 

 

TPM

+

 power 

 

Quick Startup Guide 

 

Seite en-10 

Revision: 02 

4091-D021077 

Release: 14.04.2010 

 

 

5.5  TPM

+

 power 560 V – Ratio 40 – 100 

 

Par. 

Description 

Unit 

TPMP004S  TPMP010S  TPMP025S  TPMP050S  TPMP110S 

0,07 

Speed controller proportional 
gain (Kp1) 

1/rad s-1 

0,005 

0,005 

0,01 

0,01 

0,01 

0,08 

Speed controller integral 
gain (Ki1) 

1/rad 

0,09 

Speed controller differential 
feedback gain (Kd1) 

0,00 

0,00 

0,00 

0,00 

0,00 

0.38 

1

  Current controller Kp gain 

See note 1 

0.39 

1

  Current controller Ki gain 

See note 1 

0,41 

Maximum switching frequency  kHz 

16 

16 

16 

16 

16 

0,42 

Number of motor poles 

12 

12 

12 

12 

0,46 

Motor rated current 

Arms 

1,00 

1,86 

4,00 

7,50 

21,90 

0,48 

Operating mode selector 

SERVO 

SERVO 

SERVO 

SERVO 

SERVO 

1,06 

Maximum reference clamp 

RPM 

6000 

6000 

6000 

5000 

5000 

4.05 

2

  Motoring current limit 

300 

323 

300 

440 

228 

4.06 

2

  Regen current limit 

300 

323 

300 

440 

228 

4.07 

2

  Symmetrical current limit 

300 

323 

300 

440 

228 

4,15 

Thermal time constant 

100 

200 

400 

400 

400 

4,16 

Thermal protection mode 

1 or 0 depending on application 

5,08 

Rated Speed 

RPM 

6000 

6000 

6000 

5000 

5000 

5,17 

Stator resistance 

Ohm 

40,00 

13,50 

4,00 

1,81 

0,25 

5,24 

Transient inductance (Ls) 

mH 

30,00 

18,90 

11,10 

5,10 

1,90 

5,32 

Motor torque per amp, Kt 

Nm/Arms 

0,78 

1,02 

0,97 

0,91 

1,08 

7,15 

T8 analogue input 3 mode 

th 

th 

th 

th 

th 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1

    Automatic calculation by setting #0.40 to 6 after input of R and L in #5.17 and 5.24. 

2

    Subject to static and dynamic loads as well as the lambda factor the max. acceleration motor current has to be 

reduced. We recommend a detailed calculation with Cymex.

Содержание TPM+ power

Страница 1: ...4091 D021068 01 TPM power Control Techniques Unidrive SP Quick Startup Guide 4091 D021077 Revision 02...

Страница 2: ...ontrol GmbH Customer Service Walter Wittenstein Stra e 1 D 97999 Igersheim Tel 49 0 79 31 493 10900 Fax 49 0 79 31 493 10903 E Mail service wmc wittenstein de WITTENSTEIN motion control GmbH 2010 This...

Страница 3: ...ty Instructions 4 3 3 1 General safety instructions 4 4 Type plate information identification 6 4 1 Identification plate designation 6 5 Setting the parameters 7 5 1 TPM motor feedback Resolver 7 5 2...

Страница 4: ...tating or improving operations The safety instructions symbols are described in section 3 Safety 2 4 Exclusion of liability WITTENSTEIN motion control is not liable for damages or injury caused by Imp...

Страница 5: ...nd is thus prohibited The operation of the servo actuator is prohibited if It was not installed according to regulations for example fastening bolts The servo actuator is very dirty damaged or blocked...

Страница 6: ...o actuator into operation check that there are no impurities or tools near it Maintenance DANGER An unintentional start of the machine during maintenance work can lead to serious accidents Ensure that...

Страница 7: ...tification plate designation The following specifications can be found on the identification plate Bild 4 2 A Ordering code B DC Bus voltage C Maximum current D Maximum torque at gear output E Maximum...

Страница 8: ...parameters can damage the motor feedback or the drive Parameter Function Unit TPM 004S TPM 010S TPM 025S TPM 050S TPM 110S 03 26 Speed feedback selector Slot 1 Slot 2 or Slot 3 depending on slot for S...

Страница 9: ...the motor Wrong parameters can damage the motor feedback or the drive Parameter Function Unit TPM 004S TPM 010S TPM 025S TPM 050S TPM 110S 03 26 Speed feedback selector drv 0 03 36 Drive encoder suppl...

Страница 10: ...or SERVO SERVO SERVO SERVO SERVO 1 06 Maximum reference clamp RPM 6000 6000 6000 5000 5000 4 05 2 Motoring current limit 333 315 292 334 259 4 06 2 Regen current limit 333 315 292 334 259 4 07 2 Symme...

Страница 11: ...r SERVO SERVO SERVO SERVO SERVO 1 06 Maximum reference clamp RPM 6000 6000 6000 5000 5000 4 05 2 Motoring current limit 300 323 300 440 228 4 06 2 Regen current limit 300 323 300 440 228 4 07 2 Symmet...

Страница 12: ...rating mode selector SERVO SERVO SERVO 1 06 Maximum reference clamp RPM 6000 6000 6000 4 05 2 Motoring current limit 333 314 295 4 06 2 Regen current limit 333 314 295 4 07 2 Symmetrical current limit...

Страница 13: ...rating mode selector SERVO SERVO SERVO 1 06 Maximum reference clamp RPM 6000 6000 6000 4 05 2 Motoring current limit 300 323 303 4 06 2 Regen current limit 300 323 303 4 07 2 Symmetrical current limit...

Страница 14: ...d information on cable design and the type of shielding can be found in the documentation from the servo drive manufacturer 6 1 TPM power with resolver WITTENSTEIN motion control offers pre manufactur...

Страница 15: ...7 Release 14 04 2010 6 2 TPM power with absolute encoder Heidenhain EnDat ECN1113 EQN 1125 WITTENSTEIN motion control offers pre manufactured and drag chain compatible cablesets for this servo drive P...

Страница 16: ...021077 Release 14 04 2010 6 3 TPM power with absolute encoder Stegmann SKS 36 SKM 36 WITTENSTEIN motion control offers pre manufactured and drag chain compatible cablesets for this servo drive Please...

Страница 17: ...4091 D015003 02 enAC XXXXXXXX 4091 D015003 Revision 02 WITTENSTEIN motion control GmbH Walter Wittenstein Stra e 1 97999 Igersheim WITTENSTEIN being one with the future www wittenstein de...

Отзывы: