Appendix
SP
+
ATEX MC
en-38
2022-D014985
Revision: 07
Direction of rotation
–
In- and output same direction
Mass moment of inertia J
1
[kgcm
2
]
Refers to the drive
19
0.81
0.70
0.68
0.60
0.43
0.59
24
2.2
2.1
2.1
2.0
2.1
2.0
a
No-load running torques diminish during operation
b
Refers to the center of the output shaft or flange
Tbl-25: SP
+
100, 2–stage, i = 16 – 35: Technical data for use in potentially explosive atmospheres
Technical data for SP
+
100, 2-stage, i = 40 – 100
Clamping
hub Ø
[mm]
Ratio i
40
50
64
70
100
Max. acceleration torque T
2B
[Nm]
(max. 1000 cycles per hour)
–
120
128
84
132
84
Nominal output torque T
2N
[Nm]
(At n
1N
)
–
96
102
68
106
68
Emergency stop torque T
2Not
[Nm]
(1000 times possible during the service life
of the gearbox)
–
335
335
320
335
330
Permissible average input speed n
1N
[min
-1
]
(At T
2N
)
a
–
3600
3600
3600
3600
3600
Max. input speed n
1Max
[min
-1
]
–
4500
4500
4500
4500
4500
Average no-load running torque T
012
[Nm]
(For n
1
=3000 min
-1
and gearbox
temperature 20 °C)
b
–
0.28
0.30
0.25
0.20
0.19
Max. backlash j
t
[arcmin]
–
Standard ≤ 6 / Reduced ≤ 4
Torsional rigidity C
t21
[Nm/arcmin]
–
31
Max. axial force F
2AMax
[N]
c
–
3950
Max. lateral force F
2QMax
[N]
c
–
3670
Max. tilting moment M
2KMax
[Nm]
–
340
Service life L
h
[h]
–
see Chapter 7.2.4 "Replacing the
Weight incl. standard adapter plate m
[kg]
–
7.9
Operating noise L
PA
[dB(A)]
(For n
1
= 3000 min
-1
w/o load)
–
≤ 60
Max. permissible housing temperature
[°C]
–
+80
Technical data for SP
+
100, 2-stage, i = 16 – 35
Clamping
hub Ø
[mm]
Ratio i
16
20
25
28
32
35