The hood must be installed at a max distance from the hob of 2500mm to ensure proper function. Before installation,
please inspect the hood for any product damages. Never install or use a damaged hood, please contact after-sales
service.
External motor (WS958 XM-2, WS958 W XM-2) in extraction mode:
Fit a false ceiling with a minimum distance to the solid ceiling of 279mm and a niche for the hood of 865 x 405mm.
It is possible to select which side of the hood the air suctioned should be discharged. A The air outlet pipe must be
purchased separately. Ensure that the unused exhaust outlets are closed.
Fig. 1: Draw the outline of the hole to house the ceiling-mounted hood on the solid ceiling.
Fig. 2: Make 4 holes in the ceiling according to the dimensions given in Fig. 2.
Fig. 3: Open the glass panels by pulling them cautiously as shown, and remove the grease filters before continuing the
installation.
Fig. 4: Screw the threaded bars provided into the plugs.
Fig. 5: The threaded bars are 250mm long and serve to install the ceiling-mounted hood at a distance from the solid
ceiling of between 270mm and 370mm
Fig. 6: Make the electrical connections and connect the air outlet pipe; place the ceiling-mounted hood into the niche by
inserting the threaded bars into the holes,
Fig. 7: Ensure that the outer edge of the hood is perfectly flush with the false ceiling. Insert the plates and nuts provided
into the threaded bars, making sure to tighten them securely. Reinsert the grease filters and close the panels.
Fig. 20: Connect the internal motor or the external motor’s cable to the terminal board found inside the plastic box of the
wiring. Make sure to respect the colors of cables when performing the electrical connection.
NOTE: An external motor must be installed accessibly in case service is needed.
After installation, please ensure that the motor and the light are functioning correctly.
Internal motor (WS958-2, WS958 W-2) in extraction mode:
Fit a false ceiling with a minimum distance to the solid ceiling of 330mm and a niche for the hood of 865 x 405mm.
Fig. 16: It is possible to select which side of the hood the air suctioned should be discharged, as follows: Remove the
eight fixing screws of the suctioning unit shown in fig. 16, pull the suctioning unit out by disconnecting the electric
connector, remove the cover of the air outlet hole you want to use and place the suctioning unit in it. Restore the electric
connection and secure the suctioning unit with the screws previously removed. Refit the cover on the unused air outlet
hole.
Proceed with the installation by following steps 1-20 above.
After installation, please ensure that the motor and the light are functioning correctly.
Please note:
-
The exhausting pipe must be made from a non-flammable material
-
Extraction may not be carried out through a flue, chimney or ventilation shaft, if these are also used for the
ventilation of a room with a fireplace.
-
If extraction is carried out through a chimney or ventilation shaft no longer in use, make sure to observe local
rules and regulations.
Содержание WS958 W XM-2
Страница 2: ......
Страница 4: ......
Страница 12: ...8 Måltegninger WS 958 XM 2 WS 958 W XM 2 WS 958 2 WS 958 W 2 ...
Страница 25: ...21 Målskisser WS 958 XM 2 WS 958 W XM 2 WS 958 2 WS 958 W 2 ...
Страница 38: ...34 Måttskisser WS 958 XM 2 WS 958 W XM 2 WS 958 2 WS 958 W 2 ...
Страница 54: ...50 Illustrationer illustrasjoner illustrationer illustrations ...
Страница 55: ...51 ...
Страница 56: ...Witt A S Gødstrup Søvej 9 7400 Herning Mail info witt dk tlf 70 25 23 23 ...