3.2 

Start logging using the “Wizard” 

If you are in the measurement window: 

 

Press 

 to proceed to the main menu. 

 

Select the menu item «Start Wizard» with 

 

All settings that are important for logging are indicated one after another.  
The settings can be acknowledged or altered on demand. See Section ### 3.3 for details. 

«Delete Log data» 

 Yes / No 

«Interval» 

 

 confirm time / alter time / stop Wizard with 

«Start type» 

 

 confirm setting / alter start type 

«Countdown»   

 confirm time / alter time / stop Wizard with 

.  

 

 

 

     (indication only on selection of certain «Start types» 

«Start logging»  

 Yes / No 

 

Logging will start, as soon as the actual selected start condition is fulfilled  
(see menu item «Start type», Section 3.3.2). 

During logging the display will be deactivated. 

 

3.2.1 

Check / stop a running logging 

 

To check weather a logging is in process, press 

 or 

.  

If this is the case, «Logging…» will be indicated for some seconds. 

 

To stop logging, press 

 

3.3 

The menu «Log Settings» 

In this menu, you can set a start condition for logging and the time interval for storing measurement 
values during logging. 

 

 

Select (

 

) «Log Settings» in the main menu and confirm with 

 

The menu «Log Settings» is indicated. The menu items are: 

 

 

3.3.1 

The menu item «Start logging» 

 

 

Select menu item «Start logging» in the main menu and confirm with 

 

After selection, the actual set parameters are indicated in several windows (use 

 

 to change 

between these windows). Alterations are not possible in these windows. 

After pressing 

, a security query must be confirmed with “Yes” to start logging. 

 

 

Start Wizard 

 

Log Settings  

Device Settings 

NFC Enable  

Shutdown 

Start Wizard  

Log Settings

  

Device Settings 

NFC Enable  

Shutdown 

Start logging 

Start type 

 

 

Interval  

Countdown 

Show log data 

Содержание PATBOX

Страница 1: ...Copyright WITT GASETECHNIK GmbH Co KG 2018 all rights reserved Instruction Manual for WITT PATBOX Issue 07 06 2018 This issue is not subject to change management...

Страница 2: ...logging 5 3 3 2 The menu Start type 6 3 3 3 The menu Interval 6 3 3 4 The menu Countdown 6 3 3 5 The menu Show log data 6 3 3 6 The menu Delete log data 7 3 3 7 The menu item Back 7 3 4 The menu Devi...

Страница 3: ...ement There are several methods to start a measurement Start on pressing a button start after a settable count down time expired or start on movement of the PATBOX By means of a NFC connection log dat...

Страница 4: ...he actual measured temperature The actual measured pressure The indicated measurement values are not stored With button you proceed to the main menu With buttons you proceed to the indication of store...

Страница 5: ...art type Section 3 3 2 During logging the display will be deactivated 3 2 1 Check stop a running logging To check weather a logging is in process press or If this is the case Logging will be indicated...

Страница 6: ...menu Interval In this menu you can select the time interval min 100 milliseconds max 24 hours for storing measurement values Set the desired time interval in hours minutes seconds 100 milliseconds as...

Страница 7: ...em Device info After selecting this menu item the software version and serial number will be indicated 3 5 The menu item NFC enable After selecting this menu item the device will try to establish a Ne...

Страница 8: ...charging The charging indication will be indicated some time after putting the PATBOX on the charging pad The date and time setting can be lost After charging these settings should be checked and corr...

Страница 9: ...m Show Chart Select the serial number of the desired PATBOX if there are data of more than one device Select the desire data for indication Note If you select the desired data for about 2 seconds you...

Страница 10: ...Logging interval Settable from 0 1 second to 24 hours in steps of 0 1 s Memory Flash chip Capacity 8 MB Number of records approx 600 000 Communication NFC Near Field Communication Housing Shock resis...

Страница 11: ...must accept any interference received including interference that may cause un desired operation NOTE Changes or modifications made to this equipment not expressly approved by manufacturer name may v...

Отзывы: