![WITA U 25 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/wita/u-25/u-25_original-installation-and-operating-instructions_989832023.webp)
Display HE Pumpen
Operating instrutions
WITA U 25 | U 35 | U 55 | U 75
4 Intended Use
The WITA U pumps are designed for circulating hot
water in photovoltaic systems, and are also suitable for
conveying thin liquid media in industry and commerce.
5
Specifications related to the product
5.1
Technical data U 25 | U 35 | U 55 | U 75
U 25
U 35
Maximum delivery head
2.7 m
4.0 m
Maximum flow
2.600 l/h
3.000 l/h
Power consumption P1 (W)
28 - 46
28 - 63
Supply voltage
1 x 230V 50Hz
Acoustic emission pressure level
< 40 dB(A)
Protective rating
IP 42
Thermal class
TF 110
Operating temperature
0 °C to 40 °C
Fluid temperature
+5 to 110°C
Max. system pressure
10 bar (1 MPa)
Permissible media to be pumped
Water/glycol mixture 1:1
Inlet pressure
Permissible range of application
23
Characteristic
U 25
H
(m)
4
3
2
1
0
0
1
2
3
Qm
3
/h
Characteristic
U 35
H
(m)
4
3
2
1
0
0
1
2
3
Qm
3
/h
fluid
Minimum inlet pressure
temperature
< 75 °C
0.05 bar 0.005 MPa 0.5 m
75 °C - 90 °C
0.3 bar
0.03 MPa
3.0 m
90 °C - 110 °C
1.1 bar
0.11 MPa
11.0 m
Temperature range
Permissible fluid
at maximum
temperature
ambient temperature
25 °C
5 °C to 110 °C
40 °C
5 °C to 95 °C