![WisyCom RTE25 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/wisycom/rte25/rte25_user-manual_989781008.webp)
7
TECHNICAL
SPECIFICATIONS
Switchable channels
:
16, preset in one of the following ranges (others on request):
140 ÷ 250 MHz,
300 ÷ 360 MHz,
470 ÷ 880 MHz.
Switching-window
:
15 MHz, in the 140 ÷ 250 and 300 ÷ 360 MHz ranges; 25 MHz, in the 470 ÷ 880 MHz
range.
Frequencies
:
Microprocessor controlled PLL frequency synthesizer circuit, with 25 KHz minimum step.
They are easily user-re-programmable by DOS-PC and optional “UPK 32 Programming kit”.
Frequency error
:
< ± 5 ppm, in the rated temperature range
Temperature range
:
-10 ÷ +55 °C
Modulation
:
FM, with 50 µs de-emphasis.
Nominal deviation
:
±20 KHz, with NR-system pre-set
Off
;
±40 KHz, with NR-system pre-set
On
.
Peak deviation
:
±75 KHz, with NR-system pre-set
Off;
±55 KHz, with NR-system pre-set
On.
RF output power
:
2.5 W (± 1 dB).
Spurious emissions
:
< 250 nW.
Antenna connector
:
N-F type.
Output impedance
:
50 ohm.
Audio input
:
Transformer balanced, floating (XLR3-F connector).
Audio input level
:
Micro
/
Line
switchable, and adjustable (for nominal deviation) between:
Micro
= -60 ÷ -28 dBu ( 0.77 ÷ 30 mVrms) (Input impedance = > 2 kohm)
Line
= -32 ÷ 0 dBu (20 ÷ 775 mVrms) (Input impedance = > 5 kohm)
Peak-limiter
:
Automatic, with dynamic range > 24 dB over the level set for the nominal deviation.
Option LLK:
For stereo applications, the limiter-circuits of two units can be linked by the optional
external cable.
NR-system
:
Compander circuit, can be internally pre-set (or excluded) between following modes:
ENR (
Wisycom
Extended-NR, with independent Attack- and Recovery-time), default;
NR (Standard-NR), to be compatible with other apparatus.
AF bandwidth
:
30 Hz ÷ 20 KHz.
Frequency response
:
± 0.5 dB (± 0.25 dB typ.) in the 40 Hz ÷ 19 KHz range.
Distortion
:
< 0.3 % (0.15 % typ.).
SND/N ratio
:
> 110 dB (115 dB typ.), with NR-system pre-set
On
;
> 80 dB ( 85 dB typ.), with NR-system pre-set
Off
.
(referred to the peak deviation, and measured: 22 Hz/22 KHz, RMS, unweighted).
LED indications
:
apparatus On (green LED is on);
limiter-on status (red LED is on).
Bar-graph meter
:
± KHz deviation
± dB deviation
referred to ± 20 KHz deviation.
Powering
:
9 ÷ 15 Vdc / 10 W (typ.: 900 mA @ 12 Vdc), negative ground
mains 100 ÷ 264 Vac, by means of optional PSP25-L “mains-plug” power supply.
Dimensions - Weight
:
243 x 43 mm (½ x 19”/1U standard-rack) x 226 mm depth.
Weight
:
1.5 Kg approx.