![WisyCom MRK 950 EX Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/wisycom/mrk-950-ex/mrk-950-ex_instruction-manual_989732016.webp)
Pag. 16
MRK950
dual true diversity receiver
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
LINK
HUB - SWITCH
ETHERNET
ETHERNET
Digital audio Ethersound
©
The Ethersound option on the MRK950 adds the ca
-
pability of a connection beetween the MRK950 and
an Ethersound audio distribution system. This option
adds two RJ45 connectors for the ethernet cables,
one is the input and the other is the output of the
Ethersound interface.
Link Ethernet 10/100 Mbit/s
The Ethernet interface is used to connect an MRK950
to an host PC for remote monitoring. The “WISY
-
COM MANAGER” is the PC software for the complete
remote monitoring and managing several MRK950
also connected thru an USB cascade.
WISYCOM MANAGER is able to find a configure net
-
work parameter of a MRK950 in ethernet connection
without knowing its IP address (this is done thru a
broadcast discovery). Near the ethernet connec
-
tor there are two led lamps, one for the connection
check and one for the data monitoring.
A receiver connected to a PC could be an subnet
controller for other receivers if the other receivers
are connected in a chain with USB cables as shown
on the picture in the previous page.
USB connection
The MRK950 comes with an USB 1.1 interface that
has has priority over ethernet connection. Near the
USB connector there is another connector named
LINK. This connector could be connected to the USB
port of the next MRK950 with an USB-A to USB-B
cable to build a chain of receivers. The maximum
number of receivers in a chain is four. The receiver
with the USB connector free is the subnet controller
receiver (the one in the upper position on the pic-
ture). It must be connected to a PC by means of the
USB port or by means of an ethernet connection.
Once connected, start the WISYCOM MANAGER soft
-
ware to manage the array of receivers (more details
on software manual).
NETWORK CONNECTION
Wisycom Manager software allows to monitor and
configure remotely complex systems base on
MRK950s connected in USB chain or thru ethernet
connection.
4 racks USB CASCADE
(8 receiver):
the first is the subnet controller that control up to
other 3 receiver. This entity is seen as single 8 re-
ceiver and using the ethernet port of the subnet con-
troller can also be remoted in a computer network.
This way the system has also the information on ev-
ery single MRK950s location allowing very effective
configuration and scene backup.
LINK
LINK
LINK
USB or ETHERNET
Note: it is not possible to connect more than
4 receivers MRK950 in a subnet USB
Note: If using MRK950EX with antenna
cascade (using its integrated splitter),
the
MRK950EX acting as “subnet controller”
must be also the receiver connected with
antennas and boosters
. This is to be able
to manage and monitor voltage and current
on antenna boosters.
Several USB cascade
can be connected using the
ethernet connection on each MRK950 acting as cas-
cade controller.
Hereafter an example of a 12 rack configuration,
there is no limits to the complexity manageable on
Wisycom Manager software.
Содержание MRK 950 EX
Страница 2: ...Pag 2 MRK950 dual true diversity receiver...
Страница 19: ...Pag 19 high performances microphone system...