background image

MPR30-IFB User Manual

 

 

Rev. 03

 

 

19

 

 

T

ROUBLESHOOTING

 

 

Problem 

Possible cause 

Possible solution 

“HW init failed” message 
appears on the display 

Error during the hardware initialization 
phase 

-reset the receiver, if the 
problem persists send to repair 
at Wisycom Repair Centre 

“Battery Low” message 
appears on the display 

Low level on the battery 

- change batteries or 
- recharge the batteries 

“Battery charge failed” 
message appears on the 
display 

Error during batteries charger 
(damage batteries or wrong batteries) 

- change batteries  

“I2C communication error” 
message appears on the 
display 

Communication error on bus I2C 

- send to repair at Wisycom 
Repair Centre 

“Device ID copy1 invalid 
Memory recovered” 
message appears on the 
display 

Error during the initialization phase. The 
CRC-16 check of device data (copy 1) 
detects error. 

- nothing (the receiver 
automatically replace the 
corrupt copy1 with copy2) 

“Device ID copy2 invalid 
Memory recovered” 
message appears on the 
display 

Error during the initialization phase. The 
CRC-16 check of device data (copy 2) 
detects error. 

- nothing (the receiver 
automatically replace the 
corrupt copy2 with copy1) 

“RF copy1 invalid 
Memory recovered” 
message appears on the 
display 

Error during the initialization phase. The 
CRC-16 check of RF data (copy 1) detects 
error. 

- nothing (the receiver 
automatically replace the 
corrupt copy1 with copy2) 

“RF copy2 invalid 
Memory recovered” 
message appears on the 
display 

Error during the initialization phase. The 
CRC-16 check of RF data (copy 2) detects 
error. 

- nothing (the receiver 
automatically replace the 
corrupt copy2 with copy1) 

The Serial Number of the 
receiver in the Info menu 
is UNCAL 

Error during the initialization phase. The 
CRC-16 check of device data (copy 1 and 
copy 2) detects error. 

- send to repair at Wisycom 
Repair Centre 

The errors 87 (Device ID 
copy 1 ) and 88 (Device ID 
copy 2) appear in the 
errors  list  

Error during the initialization phase. The 
CRC-16 check of device data (copy 1 and 
copy 2) detects error. 

- If the Serial Number in the 
Info menu is UNCAL, then send 
to repair at Wisycom Repair 
Centre 
- If the Serial Number in the 
Info menu is not UNCAL, 
continue to use the receiver  

The errors 89 (RF mem.  
copy 1 ) and 8A (RF meme. 
copy 2) appear in the 
errors list 

Error during the initialization phase. The 
CRC-16 check of RF data (copy 1 and copy 
2) detects error. 

- contact Wisycom for more 
information 

The receiver is not able to 
tuned on the selected 
frequency and the ON led 
indicator remains red 

Error during frequency tuning 

- try to change the frequency, if 
the problem persists send to 
repair at Wisycom Repair 
Centre 

Содержание MPR30-IFB

Страница 1: ...MPR30 IFB User Manual High performance True diversity Receiver SN ________________ Rev 03 rif FW v1 5 Date 21 March 2014...

Страница 2: ...MPR30 IFB User Manual Rev 03 1...

Страница 3: ...es scan for best channels o remote configuration utilities thru infrared or micro USB interface using Wisycom MPR30 RX Manager application o OLED display with intuitive context menu navigation extreme...

Страница 4: ...r Clean the apparatus only with dry cloths do not use liquids Report the serial number and the purchasing date in front of the manual It is needed to have proper replacement parts or accessories from...

Страница 5: ...n battery can be charged through A dedicated charger B integrated micro usb B connector For B item the charging status can be checked looking the status of LED indicator ON The receiver can be used al...

Страница 6: ...mW 16 Pin Assignment Tip left hot Ring right hot Sleeve Gnd On Off Volume control The control knob in the upper panel allows To switch the receiver ON turn the control knob volume control clockwise un...

Страница 7: ...and keep pushing to save the chosen setup EXIT Button Push this button to turn off the display During menu navigation push this button to exit from current menu escape function SYNC UP Button Push an...

Страница 8: ...p phase The receiver is locked on the select frequency the batteries charge is very low 12 lifetime Green Red blinking During a scan operation The device is doing a scan of the frequencies Blue During...

Страница 9: ...e setting and eventually adjust the settings using the Operating Menu Status display Receiver Name ex MPR30 IFB RX Group ex Gr 00 and Channel ex Ch 01 Frequency ex Fr 567 000 MHz Squelch ex Sq 9dBuV J...

Страница 10: ...an Scan BTN Channel Groups Freq View last Deploy Settings Name 12 characters ex RECEIVER 123 Quick Menu Clone Off Display Contrast 0 5 Low timeout sec 5 60 steps 5 Off timeout sec 10 120 steps 10 OFF...

Страница 11: ...f adjusting the gain of low and high frequency components bass and treble within the audio signal 1 Push UP DOWN button to increase decrease the gain of the Low frequencies 50Hz 2 Push SEL button to s...

Страница 12: ...scan function very flexible This function can be called also using the dedicated DOWN SEL buttons pushed together Squelch scan indicates the threshold below which a channel is considered as free or al...

Страница 13: ...on a chart in ascending order according to the number of the channel After the selection of the desired channel a screen appears with the selected frequency channel and group and it is possible to Se...

Страница 14: ...commend setting the frequency and then synchronize it with the transmitter Freq The Frequency scan allows to select a range of frequency to scan between a maximum and a minimum value and the step with...

Страница 15: ...to the Load clone menu or Off for disable this function if is set Off and UP or DOWN buttons are pushed nothing happens Display Contrast 0 5 Change contrast display from 0 min to 5 max Low timeout 5 6...

Страница 16: ...es during the max brightness of the display an open lock is displayed on the Status Display After the Display Low timeout the lock becomes closed and the lock volume is enabled To enable the volume se...

Страница 17: ...ed before the loading of the clone is saved on the clone named default therefore loading the default clone allows to return with the previous settings The following arrows displayed near the clone num...

Страница 18: ...limit is set automatically to the max value permitted for no lithium battery that is 100mW Info the INFO function shows many important features or information of MPR30 IFB receiver PARAMETER MEANING...

Страница 19: ...list in the Info menu only for some error see the below table NOTE1 When the receiver is reset the error information code and error type on the list are lost with the exception of errors codes 87 88...

Страница 20: ...y Error during the initialization phase The CRC 16 check of RF data copy 1 detects error nothing the receiver automatically replace the corrupt copy1 with copy2 RF copy2 invalid Memory recovered messa...

Страница 21: ...rors list load a new frequency file wdf in the frequency memory of the receiver and contact Wisycom for more information Configuration mismatch Error in the parameter memory if the error code 86 appea...

Страница 22: ...B M Band 566 654 MHz Antenna Code label 590 AWMH30 For MPR30 IFB M Band 654 798 MHz Antenna Code label 725 Other accessories available CAUSBM1 Micro USB cable to configure MPR30 IFB and to recharge li...

Страница 23: ...nstall the ENG RX Manager actives in your PC and install the new version 3 Run ENG RX Manager 4 Power up the receiver MPR30 and enable the IRDA interface a push button b push button until that Infrare...

Страница 24: ...MPR30 IFB User Manual Rev 03 23 7 If the connection is ended well the Connected icon is showed on the top of the panel and Connected on USB by UPK is displayed on the information panel...

Страница 25: ...he latest version If not uninstall the ENG RX Manager actives in your PC and install the new version 3 Run ENG RX Manager 4 Power up the receiver MPR30 5 Push Disconnected button On the Device connect...

Страница 26: ...t is possible to use the spreadsheet FREQUENCY 2010 v16 xls available on the website open the file and enable changes and macro load the wdf file clicking on READ WDF button execute the desiderate cha...

Страница 27: ...input imp 50 ohm sma type SWR 1 2 typ 1 1 4 Sensitivity 2 V 6 dB V for SND N 52 dB in the whole switching window Co channel rejection 2 5 dB Adjacent chan Sel 80 dB typical for channel spacing 200 kHz...

Страница 28: ...MPR30 IFB User Manual Rev 03 27 MECHANICAL DRAWING Note unit is mm...

Страница 29: ...MPR30 IFB User Manual Rev 03 28...

Страница 30: ...te dagli altri rifiuti La raccolta differenziata della presente apparecchiatura giunta a fine vita e organizzata e gestita dal produttore L utente che vorr disfarsi della presente apparecchiatura dovr...

Страница 31: ...MPR30 IFB User Manual Rev 03 30...

Страница 32: ...MPR30 IFB User Manual Rev 03 31 Wireless System Communications Via Spin 156 I 36060 Romano d Ezzelino Italy Tel 39 0424 382605 Fax 39 0424 382733 www wisycom com e mail sales wisycom com...

Отзывы: