- 24 -
only at
Channel A*
Channel B**
OV75M A/B= channel
1237MHz=Input frequency A/B
479.00=output frequency A/B
<1.0e-4=BER, alternating
Channel
OV75M
V1.00
busy
Channel
A/B
F-Out*
Offset**
45-862 MHz,
1 MHz steps
4-8 MHz
-Offset
Exp.: Ch A = 471,25 MHz + 8-MHz-Offset = Ch B
loop
=
Loop through mode
single
= Single output
1.000-7.499 kBaud
?Symbol rate?
Incorrect symbole rate
?????
refer to note
auto/on/off
: auto:QAM signal switches off autom.
on: signal doesn't switch off automatically.
off: signal switches to off
Out-Att*
0-10 dB
Output level, 1dB steps
OutConf*
Stuffin
on, off
- autom. insert of data bits
QAMRate
QAMCarr
QAMSpec
normal / inverse
PIDFlt 0-9
0-9,
10 filter, Hex code / off
Modules*
Displaying: modules
A: DVBS
- module
B: DVBS
- module
Dual-QAM
Mod-No*
Displaying: module number
0-9
Version*
version of basic unit,
software version module
software version QAM module
undocumented command
ModVers
Displaying: hard and software version of input modules
A: DVBS
- module
S1.0003
- software version
H1.0000
- hardware version
Insert here - input modules settings
16, 32, 64, 128, 256 QAM
type of modulation.
QAMMode
OV75M
V1.00
Ch. A
(1)
(1)
Op-ID
Operator ID,
0x0001-0xFFFF, Hex. / off
(2)
(2)
Version
V 1.00
1607020
00
Settings Dual QAM
(Key code XX2/3X with/without transport stream handling)
Operation
Select the menu item and
adjust the values in a menu line
with the UP/DOWN keys
.
Enter values and enter and exit
from menu lines with the LEFT/
RIGHT keys
.
Saving: Data are saved
automatically. Data are retained
in the case of a power failure.
GB
Modules with TS handling
1) Setting the input frequency:
the "OP-ID" and "PIDFlt turns
to OFF
2) Only for Dual QAM with TS
handling and DVB-S and/or
ASI, DVB-S2 modules