connection
28_ connection
TOPFRONT
HCV-7070R
Power Input Terminal
When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size (AWG)
#24 (0.22mm
2
)
#22 (0.33mm
2
)
#20 (0.52mm
2
)
#18 (0.83mm
2
)
Resistance value(Ω/m)
0.078
0.050
0.030
0.018
Voltage Drop (V/m)
0.028
0.018
0.011
0.006
y
As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection to the camera
may affect the performance of the camera.
Standard voltage for camera operation : DC 12V±10%, AC 24V±10%
There may be some deviation in voltage drop depending on the type of wire and the manufacturer.
M
`
Be sure to connect power only after all the installation is complete.
REC
HDD
ALARM NETWORK BACKUP POWER
CAUTIO
N
:
Be w
are
of th
e
Rated
Voltage and
Polarit
y
of th
e po
wer c
onnect
io
n.
Power Input Terminal
HCO-7070R