27
Using the soft cloth to wipe the dust which on the bearing, and then use the oil suction needle inject the oil into the
bearing and slowly roll the bearing.
7). Laser tube maintenance.
The laser tube should avoid generating incrustation which would cause water stemming. If there is incrustation,
please clean it with 20% diluted hydrochloric acid.
Light path
The light path is made of reflecting by reflector and focusing by the focus lens. The focus lens won’t be skewing; but
the skewing possibility of the three reflectors is high because they are fixed by mechanical part. So we advice
customers make sure to check up the light part before working.
Ⅶ. Regular failure and failure elimination
7.1. No laser
1. Did not turn on the laser power supply (The laser power switch is on the panel).
2. The laser path is not correct.
3. Check the ammeter state by pressing the testing key in the operator panel;
a) No current: check if the wires of the laser power supply, high-tension line and signal cable are connected well;
b) Current is available (check if the mirrors and lens);
c) Check if the water circulation system works well or not;
d) Without water: check the water chiller is electrified or damaged;
e) With water: check the water inlet and water outlet if they are connected inversely or the water pipe is broken;
4. “Test” button works well, but no ray when cutting or engraving. Please check if the signal cable is loose.
5. The laser power supply is damaged, there are two ways,
a) The fan on the laser power supply should work after turning on the switch of the supply, otherwise the laser
power supply is damaged and need to replace.
b) Check the electric wire of the laser power supply.
c) The following is the 200W laser power supply sketch map
Содержание MY-L1390
Страница 7: ...4 1 2 Technical Parameters ...