WISE CONTROL
1. General
When flow of liquid come by difference pressure from pipe line inside have a flapper on
use measuring flow.
Simple design and treatment use for medium or large flow late.
F851 is application under favor of come by difference pressure from flapper and
spring tension.
2. Standard Feature
(1) DIAMETER : 1/2" - 6"
(2) TEST PRESSURE : 10Kgf/
㎤
G(Max)
(3) MAX. OPERATING TEMP. : 60
℃
(4) ACCURACY : F
․
S ±5%
3. Characteristics
(1) It's can simplicity read inside of pipeline.
(3) Small size use can measuring large flow rate
(4) Easy for installation
(5) Easy for maintenance.
4. Installation and Maintenance
(1) When installation of flow meter doing in one flow direction.
(flow direction is installation an arrow on the body)
(2) Must be use the straight line for flow meter.
(IN Let = 3D ~ 20D , OUT Let = 3D ~ 5D)
(3) When out of order instrument and cleaning added function of by-pass.
(4) It's installation strainer for dregs and sludge
INSTALLATION & OPERATION
MANUAL
DOC.NO. : C-QIM-2731-F14
PAGE : 9/10
(2) It's Simple design and convenient to handle .
SIGHT GLASS AND FLOW INDICATOR (F851)