background image

 

 

 

SA-X DSP QUICK START GUIDE .DOCX 

- 9 - 

2022-11-22 

Network: 

This is where you will find all the networking settings. 

 

Hostname: This is the mDNS name of the box. If you change this name, the webpage will automatically update and reload. 

 

Power Conservation: 

This only applies to the SA-8 and SA-8 DSP - 

To meet low power requirements, this is enabled by 

default. Uncheck this and the Network connection will stay active even when the SA-8 is in standby. This will let the 

webpage still function regardless of if the SA-8 is On or in Standby. 

 

Configuration: DHCP is default, and the current IP address is shown. Manual will let you set a static IP address. 

NOTE

: If you press and hold the “programmer” button on the rear panel while the unit is on, these settings shown below will reset 

to the factory default. Check the amplifier owner’s manual for more details. 

 

 

 

 

Enter a custom name for the 

amplifier here and the mDNS 

name will automatically 

update and reload. 

Содержание SA-2 DSP

Страница 1: ...n your web browser and enter the IP Address of 169 254 0 8 wizard html to access the setup wizard Method Two mDNS Name We recommend that you connect one 1 SA x at a time on the network if you use the...

Страница 2: ...ic information about the amplifier Click on the Wrench Icon to open the advanced page The first time you open the advanced page it may take a few seconds to load NOTE If this or any other page does no...

Страница 3: ...System System Log Shows the last 20 events for the system Mains Power Recovery This only applies to the SA 8 and SA 8 DSP What does the SA 8 do during an unexpected power failure Power Failure is whe...

Страница 4: ...SA X DSP QUICK START GUIDE DOCX 4 2022 11 22 Home This will populate with the routing matrix automatically as the system is programmed...

Страница 5: ...SA X DSP QUICK START GUIDE DOCX 5 2022 11 22 Inputs Custom names can be entered here for each physical input or the default names can be used...

Страница 6: ...Center etc This is not where you enter the bi amp speaker settings Name Custom Name for each channel Input Sources What are the physical inputs that will be used for input into the channel Click the...

Страница 7: ...electing the Speaker Type the system will automatically create the correct EQ and Crossover Filters for the speaker Multiple speakers can use the same Input Channel but only one speaker can use an out...

Страница 8: ...X 8 2022 11 22 Speaker testing This page can be used to send test signals to any or all of the outputs Volume level of the test tone Have you ever heard full scale pink noise from all speakers You can...

Страница 9: ...Network connection will stay active even when the SA 8 is in standby This will let the webpage still function regardless of if the SA 8 is On or in Standby Configuration DHCP is default and the curren...

Страница 10: ...ration to save a copy of the currently installed system Import Configuration loads a saved configuration NOTE This will also import network settings that may make your amplifier un reachable over the...

Страница 11: ...are registered trademarks of Wisdom Audio Wisdom Audio 1572 College Parkway Suite 164 Carson City Nevada 89706 USA Telephone 775 887 8850 Fax 775 887 8820 www wisdomaudio com SA x DSP Quick Start Gui...

Отзывы: