Chapter 2: Getting Started
EN-15
2.2.3 Checking Device Received Signal Strength Indication (RSSI)
Short press the
SET
button at the back of the sensor
twice
.
The signal strength is indicated by its LED indicator.
•
RSSI devices are including Button Console, Contact Sensor, Motion Sensor,
Smoke Sensor, AI Transducer, DI Transducer, and Siren.
2.3 Device Deletion
2.3.1 Device Deletion
To remove the device binding, press the
SET
button for 5 seconds. The LED
indicator blinks green and then turns off. After few seconds, the LED indicator
blinks red and then turns off again, indicating the deletion process is complete.
You can also remove the device binding on the web console. However, it is
only applicable for non-battery-power device.
•
For CO
2
sensor, press both the
button until the screen blinks.
2.3.2 Reboot the Gateway
Unplug the power adapter from the Gateway and plug in again to reboot the
system.
2.3.3 Reset the Gateway
Press and hold the
SET
button for 15 seconds to reset all settings to the
factory default settings.
Status
LED Color and Behavior
Good
Blinks green (very quickly) for 15 seconds.
Normal
Blinks green (quickly) for 15 seconds.
Poor
Blinks green (slowly) for 15 seconds. (not recommended)
No Signal
Blinks red for 3 seconds and then turns off.
(not recommended)
Note
Содержание la5570
Страница 1: ...Wireless Home Security System User s Manual SENSORS POWER USB SD CARD WAN PAN ALARM SD CARD ...
Страница 94: ...Chapter 4 Web Management EN 94 Live view via RTSP mode Live view via HTTP mode ...
Страница 98: ...Chapter 4 Web Management EN 98 4 10 Logout This option allows you to log out of the system Select Logout ...
Страница 110: ...Chapter 6 Appendix EN 110 DI Transducer Integration Smoke Sensor Lock Switch Integration ...
Страница 111: ...Chapter 6 Appendix EN 111 Relay Switch LA5577 Power Relay Module LA5575 ...