Wire Tech WR-1004MLD Скачать руководство пользователя страница 11

       

WR-1004MLD Outdoor Optical Node Operation and Maintenance Manual

 

  

 

- 10 - 

After  connecting  the 

network,  the  images  of 

several  optical  contact 

points appear one or two 

horizontal bright traces. 

Power 

supply 

AC 

ripple 

interference  because  of  the  bad 

earth  of  equipment  or  power 

supply. 

Check grounding situation of the equipment, 

make  sure  that  every  equipment  in  the  line 

has  been  reliably  grounding  and  the 

grounding resistance must be

4Ω. 

After  connecting  the 

network,  the  received 

optical  power  of  the 

optical  contact  point  is 

unstable  and  changes 

continuously. 

The 

output  RF  signal  is  also 

unstable. 

But 

the 

detected  optical  output 

power  of  the  optical 

transmitter is normal. 

The  optical  fiber  connector  types 

do  not  match,  maybe  the  APC 

type connect to PC type.   

The  optical  fiber  connector  or 

adapter  may  be  polluted  seriously 

or the adapter has been damaged. 

1.  Check  the  type  of  optical  fiber  connector 

and  adopt  the  APC  type  optical  fiber 

connector  to  ensure  the  normal  transmission 

of optical signal.   

2.  Clean  the  polluted  optical  fiber  connector 

or  adapter.  Specific  operation  methods  see 
“Clean  and  maintenance  method  of  the 
optical fiber connector”.   

3. Replace the damaged adapter. 

 

10. Clean and maintenance method of the optical fiber active connector 

In many times, we misjudge the decline of the optical power or the reduce of optical receiver 

output level as the equipment faults, but actually it may be caused by the incorrect connection of the 
optical fiber connector or the optical fiber connector has been polluted by the dust or dirt.   

Now  introduce  some  common  clean  and  maintenance  methods  of  the  optical  fiber  active 

connector. 

1.

 

Carefully  pull  off  the  optical  fiber  active  connector  from  the  adapter.  The  optical  fiber  active 
connector should not aim at the human body or the naked eyes to avoid accidental injury. 

2.

 

Wash carefully with good quality lens wiping paper or medical degrease alcohol cotton. If use 
the medical degrease alcohol cotton, still need to wait 1~2 minutes after wash, let the connector 
surface dry in the air.

 

3.

 

The  cleaned  optical  fiber  active  connector  should  be  connected  to  optical  power  meter  to 
measure output optical power to affirm whether it has been cleaned up.

   

4.

 

When connect the cleaned optical fiber active connector back to adapter, should notice to make 
the force appropriate to avoid the ceramic tube in the adapter crack.

 

5.

 

If the output optical  power is  not  normal  after cleaning, should  pull off the adapter and clean 
the other connector. If the optical power still low after cleaning, the adapter may be polluted, 
clean it. (Note: Be carefully when pull off the adapter to avoid hurting inside fiber.

6.

 

Use the dedicated compressed air or degrease alcohol cotton bar to clean the adapter. When use 
the compressed air, the muzzle of the compressed air tank should aims at the ceramic tube  of 
the adapter, clean the ceramic tube with compressed air. When use degrease alcohol cotton bar, 
carefully insert the alcohol cotton bar into the ceramic tube to clean. The insert direction should 
be consistent, otherwise can not reach ideal cleaning effect.

 

Содержание WR-1004MLD

Страница 1: ... do o oo o or r r O O Op p pt t ti i ic c ca a al l l N N No o od d de e e O O Op p pe e er r ra a at t ti i io o on n n a a an n nd d d M M Ma a ai i in n nt t te e en n na a an n nc c ce e e M M Ma a an n nu u ua a al l l 2 20 01 16 6 1 1 V Ve er rs si io on n 1 1 ...

Страница 2: ...DOCSIS EOC networking scheme 3 Technique Parameter 3 1 Link Testing Conditions The performance parameters of this manual according to the measuring method of GY T 194 2003 Specifications and methods of measurement on optical node used in CATV systems and tested in the following conditions 1 Forward optical receive part with 10km standard optical fiber passive optical attenuator and standard optica...

Страница 3: ...B 0 75 Rated Output Level dBμV 108 when the optical AGC control range is 2 8 Max Output Level dBμV 114 when the optical AGC control range is 2 5 Output Return Loss dB 85 550MHz 16 550 1000MHz 14 Redundant Receiver Isolation dB 75 Output Impedance Ω 75 Return Part Optical Parameters Optical Transmit Wavelength nm 1310 10 1550 10 or specified by the user Laser Type DFB or FP laser Output Optical Pow...

Страница 4: ...gain dB 0 1 Port CMTS_US OUT Isolation forward path CMTS_US return path output dB 70 General Performance Power voltage V A AC 150 265 V B AC 35 90 V Feed current through A 10 Operating temperature 40 60 Storage temperature 40 70 Relative humidity Max 95 no condensation Consumption VA 42 Dimension mm 460 L 282 W 175 H 4 Block Diagram 5 Relation Table of Input Optical Power and CNR ...

Страница 5: ...WR 1004MLD Outdoor Optical Node Operation and Maintenance Manual 4 ...

Страница 6: ...WR 1004MLD Outdoor Optical Node Operation and Maintenance Manual 5 6 Function Display and Operating Instruction ...

Страница 7: ...wer module 1 socket 13 220Vac input 14 The RF output test port 20dB of forward path optical receiver modules 15 RF output of forward path optical receiver modules 16 The RF input interface of return path optical transmit modules 1 17 The RF input interface of return path optical transmit modules 2 18 Power 1 fuse 19 Power module 1 20 Power 2 fuse 21 Power module 2 22 Forward path optical receiver ...

Страница 8: ...t port 20dB 13 Forward path RF input 14 Port 4 return path input test port 20dB 15 Return path RF output 2 16 Return path RF output 1 17 Mode setting and attenuation jumper 18 Return path components 19 Port 3 return path input test port 20dB 20 Port 2 return path input test port 20dB 21 Port 2 forward path output test port 20dB 22 Port 2 23 Port 2 feed fuse 24 AC60V independent feed port 25 Handle...

Страница 9: ...t the computer and responder can be direct connected and change the computer IP to 192 168 1 XXX XXX is any number from 0 to 255 except 168 start upper computer network management software then search the device and log in 3 Right click device icon and choose modify the device IP 4 Enter new IP address gateway and subnet mask 5 Click modify then exit it is done There will show new IP address and g...

Страница 10: ...h 4 The C N index of system link signal is too low 1 Check the received optical power of the optical contact point and make appropriate adjustments to make it in the specified range 2 Improve the optical received power of the optical contact point by cleaning the optical fiber connector or adapter etc methods Specific operation methods see Clean and maintenance method of the optical fiber connecto...

Страница 11: ...the optical fiber connector or the optical fiber connector has been polluted by the dust or dirt Now introduce some common clean and maintenance methods of the optical fiber active connector 1 Carefully pull off the optical fiber active connector from the adapter The optical fiber active connector should not aim at the human body or the naked eyes to avoid accidental injury 2 Wash carefully with g...

Страница 12: ... unavoidable environment reasons we will responsible maintenance but ask suitable material cost 2 When the equipment breaks down immediately contact local distributor or directly call our technical support hotline 86 0571 82576002 18967160936 3 The site maintenance of the fault equipment must be operated by professional technicians to avoid worse damage Special notice If the equipment has been mai...

Отзывы: