WIPCOOL R4 Скачать руководство пользователя страница 3

03

04

feeling for more

feeling for more

3.2 Operating Instruction 

3.2.1 Check Before Operation

(Only qualified service personal should operate this unit , may require the user to be 
licensed for some countries )

Working-spot should have good lighting and Atmospheric conditions.   

Make sure the charging refrigerant oil from the oil tank is the same as the type 

     indicated on the nameplate. 

 Make sure with the correct voltage as the same as nameplate.

3.2.2 Oil Charging Process 

3) Open the oil charging valve , switch on the oil pump to start to charge the oil. 
4) Running the compressor to review if the oil level . pressure . oil temperature is under 
    normally conditions, and do the adjustment if necessary.
5) Remove the oil tank .oil pump and outlet hose if everything is fine, wipe out the rest
    oil inside hose and pump. Pack them with sealed plastic bag ,then keep the 
    compressor running again. 

R4

R6

1.5m 
Outlet tube

1/4"SAE

3/8"SAE

Portable 

Toolbox

1.5m 
Outlet tube

1/4"SAE

3/8"SAE

Portable 

Toolbox

3.1.3 Accessories

3.1.4 Product Indication Chart

Pressure Gauge

Pressure 

Relief Valve

Oil Return Tube

Oil Inlet Pipe

Non-slip Handle

Motor

Shockproof Stand

Pump Head

Non-slip Handle

Motor

Shockproof Stand

Pump Head

Oil Outlet

Oil Return Valve

Oil Inlet 

1) Clean the inlet and outlet hose to protect the oil mix,connect to the oil pump,then 
     insert the inlet hose to the tank.
2) Switch on the pump for suction oil and discharge the air from the inlet hose and 
   pump body,then switch off the pump once make sure no air inside

(

Judgment 

   Principle: The discharged oil has no foam or obvious air discharge noise, proves that 
   the air has been discharged ).  Connect the outlet hose to the oil charging valve of 
   compressor. 
3) Open the oil charging valve , switch on the oil pump to start to charge the oil. 
4) Running the compressor to review if the oil level . pressure . oil temperature is under 
    normally conditions, and do the adjustment if necessary.
5) Remove the oil tank .oil pump and outlet hose if everything is fine, wipe out the rest
    oil inside hose and pump. Pack them with sealed plastic bag ,then keep the 
    compressor running again. 