WIPCOOL P16 Скачать руководство пользователя страница 3

02

03

feeling for more

feeling for more

P16

100V-230V~/50-60Hz

10m

32L

/

h

35ml

19dB(A)

0

℃~

50

45000btu/hr

21dB(A)

P32

12

10

8

7

6

2

0

5

10

15

20

25

30

35 40

P32

P18

4. Flow Rate Chart

P16

P32

0m

24

40

2m

20

36

4m

18

26

6m

16

22

8m

12

18

10m

8

14

1. Explosion Diagram

126

12

12

7

47

5

3

1

6

7

7

12

17

85

6

4

8

.3

40

No

.

1

2

3

4

No.

5

6

7

8

No.

9

10

11

Part Name 

Water inlet pipe

 Tank

 Filter net

 Upper cover

Part Name 

Upper cover plate

 Air hole(

φ

6x20)

 Water pipe(

φ

6x1500)

Induction signal line

Part Name 

  

Power cord

 Water outlet pipe

Condensate pump 

assembly

2. Dimension

3. Technical Data

Model

Voltage

Discharge head(Max.)

Flow rate(Max.)

Tank capacity

Mini splits up to

Sound level at 1m

Ambient temp.

Model

Performance(l/h@head)

Meters head(m)

Flow(L/h)

16L

/

h

30000btu/hr

Содержание P16

Страница 1: ...OPERATION MANUAL feeling for more WENLING WIPCOOL REFRIGERATION EQUIPMENT CO LTD Website www wipcool com feeling for more Reliable And Durable Silence Running P16 P32 CONDENSATE PUMP ...

Страница 2: ...e condensate pump to avoid loss caused by power failure or water leakage 3 Non professional personnel should not install it to avoid danger 4 The condensate pump is not waterproof Do not place it in the open air outdoors or in a place prone to flooding 5 The condensate pump power supply needs to be independent to maintain permanent power supply For details of connecting with air conditioning syste...

Страница 3: ...7 53 16 7 7 12 17 85 6 48 3 40 No 1 2 3 4 No 5 6 7 8 No 9 10 11 Part Name Water inlet pipe Tank Filter net Upper cover Part Name Upper cover plate Air hole φ6x20 Water pipe φ6x1500 Induction signal line Part Name Power cord Water outlet pipe Condensate pump assembly 2 Dimension 3 Technical Data Model Voltage Discharge head Max Flow rate Max Tank capacity Mini splits up to Sound level at 1m Ambient...

Страница 4: ...re the tank is placed smoothly and the outlet pipe of the air conditioner is tightly connected with the water pipe of tank as shown below 3 Connect the vent pipe with the air hole as shown below 4 Place the pump in the position beyond the ceiling as shown below 5 The use of shockproof materials ensure the water tank and condensate pump stuck firmly low vibration to avoid noise 6 Pay attention to t...

Страница 5: ...to the water outlet tie the water pipe make sure that the discharge head is less than 8m and the length of the water pipe is less than 25m as shown below 9 The condensate pump is equipped with a signal indicating light When the pump is working and draining normally the green light is on When the water level is in alarm the red light is on as shown below 2M 10 Power supply wiring in order to avoid ...

Страница 6: ...tion is not horizontal 2 There is sludge inside tank 1 A B C WARNING Problem Cause Action Pump makes loud noise Pump can t start working Adjust the tank make it level Clean the inside of tank and probe surface 1 The water is siphoning back in the pump Check whether the outlet pipe is lower than pump thus result in siphoning raise the condensate pump position 1 Installation is not horizontal 2 The ...