SERVICE MANUAL & ICA
WIPLINE 3730 & 3900 FLOATS
Page 40
Revision K
P/N 1002551
As general inspection guidelines, each of the following areas should be inspected for their own unique attributes:
Movable Parts
For lubrication, servicing, security of attachment, binding, excessive wear, safetying, proper operation, proper
adjustment, correct travel, cracked fittings, security of hinges, defective bearings, cleanliness, corrosion,
deformation, sealing, and tension.
Fluid Lines and Hoses
For leaks, cracks, dents, kinks, chafing, security, corrosion, and deterioration.
Metal Parts
For security of attachment, cracks, metal distortion, broken welds, corrosion, condition of paint, and any other
apparent damage.
Wiring
For security, chafing, burning, defective insulation, loose or broken terminals, corroded terminals.
Bolts in Critical Area
For corrosion, correct torque when installed, or when visual inspection indicates a need for a torque check.
Nut torque should be applied depending on the hardware application, unless the torque is specified for a certain
joint in this manual or installation drawings.
**A Torque of 80% should be used when Tef-Gel is applied to the bolt.
Some additional general maintenance areas are as follows:
Nose and Main Gear Tracks
Clean and lubricate with a dry teflon coating spray.
Содержание Wipline 3730
Страница 28: ...SERVICE MANUAL ICA WIPLINE 3730 3900 FLOATS Page 28 Revision K P N 1002551 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 32: ...SERVICE MANUAL ICA WIPLINE 3730 3900 FLOATS Page 32 Revision K P N 1002551 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 36: ...SERVICE MANUAL ICA WIPLINE 3730 3900 FLOATS Page 36 Revision K P N 1002551 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 46: ...SERVICE MANUAL ICA WIPLINE 3730 3900 FLOATS Page 46 Revision K P N 1002551 THIS PAGE INTENTIONALLY LEFT BLANK ...