WPC 1000 User Manual
1125100
Installation
2-27
Place the magnet temporarily on the crankshaft or other mounting surface while you set the
gap between the switch face and the magnet. After tightening down the bracket’s mounting
screws, remove the magnet and put it in a safe place until you mount it permanently.
Wiring the Overrun Sensor Switch
Run the cable for the magnetic switch through conduit to the WPC 1000. Connect the wires to
terminal blocks on the WPC 1000 Control board, as shown in Table 2-2 and Figure 3 at the
end of the manual.
Figure 2-15. Overrun Sensor Magnetic Switch: Installation Example
You can run both the resolver wires and the overrun limit sensor cable through the same conduit.
If you do so, wait to cut the cable and wires until both the resolver and the overrun limit sensor are
installed.
Table 2-2. Overrun Sensor Switch Wiring Connections
Pin #
Signal
Wire Color
7
Overrun input to WPC 1000
White
12
Ground
Black
36
+24 Vdc
Red
Crankshaft
Gap between
magnet and
magnetic switch
1/8 to 3/16
Crankshaft
Press
Magnetic switch
Magnet
Mount temporarily
with tape.
Hard mount later.
Diameter
4-6
NOTICE
Содержание WPC 1000
Страница 17: ...1125100 WPC 1000 User Manual xii Table of Contents ...
Страница 69: ...1125100 WPC 1000 User Manual 2 42 Installation Figure 2 22 One hand Control Switch Mounting Dimensions ...
Страница 99: ...1125100 WPC 1000 User Manual 2 72 Installation ...
Страница 207: ...1125100 WPC 1000 User Manual A 18 Extracts from OSHA and ANSI ...
Страница 217: ...1125100 WPC 1000 User Manual G 6 Glossary ...
Страница 223: ......
Страница 224: ......
Страница 225: ......
Страница 226: ......
Страница 227: ......
Страница 228: ......
Страница 229: ......
Страница 230: ......
Страница 231: ......
Страница 232: ......
Страница 233: ......
Страница 234: ......
Страница 235: ......