2-25
Connecting Programmable Cam Channels
If you have purchased the ProCamPAC option with SmartPAC 2, you have received a
separate output assembly for wiring up to sixteen cam channels to your equipment. The
assembly contains the relays that open and close at the angles you set in SmartPAC 2, turning
your equipment on and off. Different types of relays can be used, depending on the voltages
of your equipment and your special needs.
To mount the ProCamPAC Output Assembly and wire it to the ProCamPAC board inside the
SmartPAC 2 control, follow the instructions below. These instructions may be used with
either the 8- or 16-channel ProCamPAC board. Refer to Table 2-7 and Table 2-8, page 2-28
for wiring connections. A wiring diagram is provided in Figure 3 at the end of the manual.
1.
Select a convenient location for running conduit from the ProCamPAC Output Assembly
to the equipment that it will control.
2.
Mount the output enclosure, using the mounting holes on the flanges as shown in
Figure 2-14, page 2-26.
3.
Select the relays to be used with each channel. Relays should already be plugged into the
Cam Outputs board (see Figure 2-15, page 2-27), each relay labelled with its type (i.e.,
standard or solid state).
Standard relays can only be plugged into the slots labeled K301 through K305, K307,
K309, and K311, which are channels 1-8. Optional solid state relays can only be plugged
into slots labeled K306, K308, K310, and K312, which are channels 5-8.
Do not mix standard and solid state relays in channel locations 5-8. For example, if you
plug a solid state relay into channel 5 (location K306), you cannot plug a standard relay
into location K305. See Figure 2-15.
PROGRAMMABLE CAM SWITCH NOT FOR SAFETY USE
Use SmartPAC 2’s programmable cam switch to control auxiliary functions only. The SmartPAC 2
programmable cam capability should never be used to provide timing signals for any safety use
including clutch/brake control or muting of light curtains. Failure to comply with these instructions
will result in death or serious injury.
BOARD DAMAGE OR SHORT CIRCUIT WHEN MOUNTED WITHOUT ENCLOSURE
• Mount the cam output assembly in a clean area where it will be safe from damage.
• Provide at least 0.5 in. (12.7 mm) clearance between the back of the Cam Outputs board and
any metal surface.
Failure to comply with these instructions could result in property damage.
DANGER
!
CAUTION
Содержание SmartPAC2
Страница 21: ...1126700 SmartPAC 2 User Manual xviii Table of Contents ...
Страница 143: ...1126700 SmartPAC 2 User Manual 4 46 Initialization Mode ...
Страница 197: ...1126700 SmartPAC 2 User Manual 5 54 Program Mode ...
Страница 233: ...1126700 SmartPAC 2 User Manual 6 36 Run Mode ...
Страница 245: ...1126700 SmartPAC 2 User Manual 7 12 Fault Messages ...
Страница 271: ...1126700 SmartPAC 2 User Manual B 12 Updating SmartPAC 2 Firmware ...
Страница 309: ...1126700 SmartPAC 2 User Manual E 6 Replacing SmartPAC 2 PC Board ...
Страница 379: ......
Страница 380: ......
Страница 381: ......
Страница 382: ......
Страница 383: ......