2
|
89014665; 2022-04
|
Assembly instructions
3
Connecting the dosing tubes and suction tube
Terminals
1
6
4
5
2
3
Item
Name
Note
1
Entries for hoses and cables
Rear view of the UF-M
2
Connection for detergent dosing hose
View of UF-M from the right
3
Connection for defoamer dosing hose
View of UF-M from the right
4
Plug for detergent suction tube with empty indication
Front view of UF-M, white plug
5
Plug for rinse aid suction tube with empty indication
Front view of UF-M, blue plug
6
Connection for rinse aid dosing hose
Front view of the UF-M
Connections for detergent and rinse aid dosing for hoses with an inner diameter of 5 mm are available on the warewasher.
Ø
Disconnect the warewasher from the electrical mains supply and secure against unintended activation.
Ø
Remove the front and right-side cover from the warewasher.
Ø
If present, remove Winterhalter dosing device and insulate electrical connections.
Ø
Install the dosing device on-site.
Ø
Lead the dosing hose and the connection cable through at the intended point on the back of the warewasher chassis (1).
Ø
Fasten detergent dosing hose to detergent connection (2) with wire hose clip.
Ø
Fasten the rinse aid dosing hose to the rinse aid connection (6) with a wire hose clip.
Ø
Connect the connection cable of the suction tube on the plug (4 / 5).
Ø
Ensure that the dosing hose and connection cable are guided kink-free.