2

 | 

89014665; 2022-04

 | 

Assembly instructions

3

Connecting the dosing tubes and suction tube

Terminals

1

6

4

5

2

3

Item

Name

Note

1

Entries for hoses and cables

Rear view of the UF-M

2

Connection for detergent dosing hose

View of UF-M from the right

3

Connection for defoamer dosing hose

View of UF-M from the right

4

Plug for detergent suction tube with empty indication

Front view of UF-M, white plug

5

Plug for rinse aid suction tube with empty indication

Front view of UF-M, blue plug

6

Connection for rinse aid dosing hose

Front view of the UF-M

Connections for detergent and rinse aid dosing for hoses with an inner diameter of 5 mm are available on the warewasher.

Ø

Disconnect the warewasher from the electrical mains supply and secure against unintended activation.

Ø

Remove the front and right-side cover from the warewasher.

Ø

If present, remove Winterhalter dosing device and insulate electrical connections.

Ø

Install the dosing device on-site.

Ø

Lead the dosing hose and the connection cable through at the intended point on the back of the warewasher chassis (1).

Ø

Fasten detergent dosing hose to detergent connection (2) with wire hose clip.

Ø

Fasten the rinse aid dosing hose to the rinse aid connection (6) with a wire hose clip.

Ø

Connect the connection cable of the suction tube on the plug (4 / 5).

Ø

Ensure that the dosing hose and connection cable are guided kink-free.

Содержание UF-L

Страница 1: ...ng personnel in handling the dosing device and point out safety notes 1 4 Improper use Children must not be allowed to play with the dosing device Do not install dosing devices inside or on cover elements of Winterhalter warewashers Winterhalter Gastronom GmbH assumes no liability for any damage caused by improper use of the dosing device To avoid damaging the warewasher and to achieve a good wash...

Страница 2: ...d dosing for hoses with an inner diameter of 5 mm are available on the warewasher Ø Disconnect the warewasher from the electrical mains supply and secure against unintended activation Ø Remove the front and right side cover from the warewasher Ø If present remove Winterhalter dosing device and insulate electrical connections Ø Install the dosing device on site Ø Lead the dosing hose and the connec...

Страница 3: ... for the measuring electrode at position 1 Ø Deburr the drillhole Ø Remove drilling swarf from the interior of the warewasher Ø Install measuring electrode Ø Lead the connection cable of the measuring electrode to the dosing device 4 2 Assemble injection hose for dosing device for powder Ø Open door Ø Remove the lower wash arms strainer and filter cylinder Ø Line the interior of the tank with clot...

Страница 4: ... 5 5 4 3 2 1 Item Name Note 1 L1 Continuous voltage phase 1 2 N Neutral phase 2 3 RINSE For rinse aid dosing device 4 WASH For detergent dosing device type dependent 5 FILL For detergent dosing device type dependent Depending on the configuration of the transfer strip voltage is present at the RINSE and FILL terminals Terminal Voltage present Condition Restriction FILL While machine fills Hood clo...

Страница 5: ... your PIN incorrectly five times in a row input will be blocked for 2 minutes Set parameters 1 2 3 4 5 6 Item Name 1 Parameters 2 Scroll keys to change parameters 3 Parameter value 4 Scroll keys for setting the parameter value 5 Confirm input 6 Back button P704 Detergent dosing device Depending on the configuration of the transfer strip with P704 voltage is present at the FILL terminal Setting Des...

Страница 6: ...er Rinse water consumption l rack The rinse water consumption depends on the on site conditions and is adjusted during commissioning Specified values correspond to the factory setting under ideal conditions Machine type UF M UF L UF XL Standard 4 7 7 0 Energy 4 7 7 0 HighTemp 5 5 9 0 Tank capacity litres UF M UF L UF XL 69 138 Flow rate solenoid valve 4 l min ...

Страница 7: ... dosed in parallel with the opening time of the solenoid valve Detergent is then dosed during the initial filling of the tank and with each rinse The output must be adjusted to the flow rate of the solenoid valve Calculating the output Flow rate solenoid valve l min x desired concentration ml l output ml min Example 4 l min x 3 0 ml l 12 0 ml min Ø Connect to the FILL terminal 4 Ø Set output on th...

Отзывы: