Commissioning
|
5
|
English
Operating instructions CTR Series
|
89014478; 2020-06
|
29
Establishing equipotential bonding
Ø
Connect the warewasher to the on-site equipotential bonding system.
Ø
Position of the connecting screw (1) see drawing.
1
5.3
Connecting external dosing devices
Danger
Electric shock from live components
A fatal electric shock can occur when the warewasher and its additional devices are connected to the elec-
trical mains supply.
Ø
The warewasher and its additional devices may be connected to the electrical mains supply only by a
specialist company registered within the electrical trade and approved by the energy supplier.
Ø
All locally applicable standards and regulations must be observed during the connection to the electrical
mains supply.
Ø
When performing installation and maintenance work as well as repairs, unplug the warewasher from the
mains supply. Check that there is no voltage present.
5.3.1 Terminals
5
4
3
2
1
Item Name
1
Connection for detergent
2
Connection for rinse aid
3
Connection for external dosing devices
4
Connection for suction tube rinse aid
5
Connection for suction tube detergent