background image

 

 

   

 Winston Foodservice | 2345 Carton Drive | Louisville, Kentucky 40299

 

 

 

       800.234.5286 | +1.502.495.5400 | www.kfcfryers.com

          

  Page 6 of 8

 

 

                            

4272y185rev13_01-20-17_instructions_fryer_maintenance_kfc

      

High Limit Mounting acceptable = Pass High Limit Thermostat Inspection

      

High Limit Mounting not acceptable = Fail and Remove Fryer from Use until Repaired

      

3. 

Heater Inspection 

- Inspect heaters to ensure that all three heaters are securely mounted in their clamps

    and they are not bent and obstructing operation through the use of a basket, cleaning, or any other

    normal operational use.

 

All Heaters are secured and acceptable = Pass heater inspection

 

Heaters not acceptable, but not obstructing = Fail and Repair Promptly

 

Heaters not acceptable and obstructing = Fail and Remove Fryer from Use until Repaired 

4. 

Probe Inspection

 - Inspect to ensure proper temperature probe position (Fig. O). Inspect to ensure that

    the probe is not missing, cracked, or bent. 

     

Probe acceptable = Pass Probe Inspection

     

Probe not acceptable = Fail and Repair Promptly

5. 

Power Cord Inspection 

- Inspect power cord and plug for loose or frayed connections. Check for

    cracked plug.

 

Plug and Cord acceptable = Pass Power Cord Inspection

 

Plug and Cord not acceptable = Fail and Remove Fryer from Use until Repaired

Fig. O - Temperature Probe

Winston Probe

Fastron Probe

Содержание Collectrmatic

Страница 1: ...e The defined useful life of a Collectramatic Pressure Fryer is 25 years from date of manufacture Any Collectramatic Pressure Fryer that has reached its useful life is to be decommissioned immediately either through physical destruction or transformation of the pressure fryer into an open fryer through the use of the defined process If any of the following criteria apply to the Collectramatic Pres...

Страница 2: ...f the front panel of the fryer If no ID tag is present or the ID tag was replaced with an upgrade control kit the original serial number is etched onto the front right side of the fryer pot rim A serial tag from an upgrade control kit can NOT be used to determine useful life Step 2 Inspect Pressure Components Fryer should be emptied of oil and cooled to room temperature prior to inspection 1 Lid I...

Страница 3: ...F to ensure that there are no cracks or broken welds Ensure that there is a gasket or food grade silicone caulk between the fryer top and Fig F Front Latch Block Fig G Front Block Gasket Front Latch acceptable Pass Front Latch Inspection Silicone Gasket missing Fail and Repair Promptly Front Latch not acceptable Fail and Remove Fryer from Use until Repaired 3 Rear Block Inspection Inspect Rear Blo...

Страница 4: ... weight end is rounded at bottom and vent block does not have a vent ball being used Fig J Fig K Fig J Correct Parts Fig K Incorrect Parts Dead Weight Vent Block acceptable Pass Vent Inspection Vent area dirty Fail and Repair Promptly Incorrect Dead Weight or Vent Block Fail and Remove Fryer from Use until Repaired 5 Collector Inspection Remove Collector Fig L to ensure that there are not any crac...

Страница 5: ... Pot Inspection Pot not acceptable Fail and Remove Fryer from Use until Repaired Step 3 Operation Component Inspection 1 Drain Valve Inspection Inspect Drain Valve Fig M for shortening leaks or missing components If leaking exists determine if leaking is internally on the drain itself externally from fryer mounting or unknown Drain Valve acceptable Pass Drain Valve Inspection Drain Valve Leaking I...

Страница 6: ...operational use All Heaters are secured and acceptable Pass heater inspection Heaters not acceptable but not obstructing Fail and Repair Promptly Heaters not acceptable and obstructing Fail and Remove Fryer from Use until Repaired 4 Probe Inspection Inspect to ensure proper temperature probe position Fig O Inspect to ensure that the probe is not missing cracked or bent Probe acceptable Pass Probe ...

Страница 7: ...20 17_instructions_fryer_maintenance_kfc Labels Present and Readable Pass Label Inspection Labels not Visible or Readable Fail and Repair Promptly Fig P Backsplash Label Fig Q Lid Lock Label Fig R Front Panel Labels Step 4 Safety Labels 1 Label Inspection Inspect all required labels Fig P Q R to determine that they are present and readable ...

Страница 8: ...es 5 Brush 6 Heat Plate Part Description Part Part Description Part Backsplash Label PS1318 Heater 230V PS2300 Brush PS1120 High Limit Clamp PS1744 Collector PS1206 High Limit Thermostat PS2438 Collector Gasket PS1892 5 Label Kit except backsplash PS2683 Displacer Tool PS1209 Lid Assembly PS1459 Drain Hook PS1154 Lid Gasket PS1891 5 Drain Valve PS1066 Lid Handlebar PS1168 Fast Probe N A Lid Lock P...