Winsen ME4-H2S Скачать руководство пользователя страница 5

Zhengzhou Winsen Electronics Technology Co., Ltd

www.winsensor.com

Tel: 86-371-67169097/67169670 Fax: 86-371-60932988

Email:

[email protected]

Fig5.Output of sensor at different temperature

Fig6.Zero output of sensor at different temperature

Cross Interference

ME4-H

2

S sensor also can respond to other gases besides target gas H

2

S. Following data are

the response characteristics of the sensor to interferential gases at certain concentration for
your reference.

Stable2. Cross interference

Interferential Gas

Concentration

ME4-H

2

S

CO

200ppm

0.5 ppm

Cl

2

10 ppm

-0.7 ppm

C

2

H

4

400 ppm

0.3 ppm

H

2

10000 ppm

5 ppm

Alcohol

1000 ppm

0.3 ppm

NH

3

50 ppm

-0.3 ppm

H

2

S

20 ppm

1.6 ppm

PH

3

20 ppm

14 ppm

Methanal

10 ppm

2.5 ppm

Benzene

100 ppm

0.2 ppm

Methanol

200 ppm

0.15 ppm

Cautions!

Tin soldering is prohibited.

Before using, power on to aging for more than 48 hours is necessary.

Pins can’t be broke off or bent.

Don’t disassemble the sensor to avoid the damage caused by electrolyte leakage.

Avoid contacting organic solvent (including

Silicone rubber and other adhesive

), coatings, medicine,

oil and high concentration gases.

All the electrochemical sensors shall not be encapsulated completely by resin materials, and

shall not immerse in pure oxygen environment, otherwise, it will damage the function of sensor

All electrochemical sensors shall not be applied in corrosive gas environment, or the sensor will

be damaged

Zero calibration should be finished in clean air.

During test and usage, sensors should avoid the gas inflow vertically

The side for inflow can’t be choked and polluted.

The laminating film above the sensor surface can’t be uncovered and damage.