Winsen ME4-H2S Скачать руководство пользователя страница 3

ME4-H

2

S Hydrogen Sulfide Gas Sensor

Profile

ME4-H

2

S hydrogen sulfide gas sensor is constant potential

electrolysis type. Oxidation-reduction reaction with
hydrogen sulfide and oxygen take place respectively on
the working electrode and on the counter electrode. The
process releases electric charge and generates current.
The current is in direct proportion to the concentration of
hydrogen sulfide. So the concentration of the target gas
could be got by measuring the value of current.

Features

Low power consumption, high precision, high sensitivity, wide linear range,
good anti-interference ability, excellent repeatability and stability.

Main applications

It is used for hydrogen sulfide detection in industrial occasions, mine and environmental
protection field.

Technical Parameters

Stable1.

Detection Gas

Hydrogen Sulfide(H2S)

Detection Range

0

100ppm

Max range

500ppm

Sensitivity

(0.8±0.15)µA/ppm

Resolution

0.1ppm

Response Time(T

90

)

30S

Bias Voltage

0mV

Load Resistance

10Ω(recommended)

Repeatability

2

Output value

Stability(/month)

2

Output Linearity

Linear

Zero drift(-20

℃~

40

)

≤0.2ppm

Temperature range

-20

℃~

50

Humidity range

15

﹪~

90

RH

Pressure range

standard atmospheric pressure±10

Lifespan

2years(in air)