Winnix Technologies HYM740 Скачать руководство пользователя страница 7

                                                                                  RFID Reader Module 

- 7 - 

 
• The module must be installed and used in strict accordance with the manufacturer’s instructions 
as described in the user documenta on that comes with the module 
 
.• The end user manual for the 

fi

nal host product operating with this transmitter must include 

operatng instructions to satisfy RF exposure compliance requirements. e.g 
 
Radiofrequency radiation exposure Information: 
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled 
environment. This equipment should be installed and operated with minimum distance of 25 cm 
between the radiator and your body.This transmitter must not be colocated or operating in 
conjunction with any other antenna or transmitter 
 
.• When the 

fi

nal host product operating with this transmitter deviate from above, installation of 

this module into speci

fi

fi

nal hosts may require the submission of a Class II permissive change 

application containing data pertinent to RF Exposure, spurious emissions, ERP/EIRP, and 
host/module authen ca on, or new application if appropriate 
 
Feel free to contact us if additional guidance is required. 
Manual Requirements according 15.19 / RSSGEN 
This device complies with Part 15 of the FCC Rules [and with Industry Canada licence exempt 
RSS standard(s)]. 
Operation is subject to the following two conditions: 
(1) this device may not cause harmful interference, and   
(2) this device must accept any interference received, including interference that may cause 
undesired opera on. 
Manual Requirements according 15.21 
Changes or modi

fi

 ca ons made to this equipment not expressly approved by (manufacturer name) 

may void the FCC authorization to operate this equipment. 

Environment requirement 

No 

Item 

Technical data 

Unit 

Remark 

Working 

temperature 

-25

+75 

 

 

Storage 

temperature 

-40

+85 

 

 

Relative 

humidity 

10%

90% 

RH 

 

 
 

Содержание HYM740

Страница 1: ...UHF RFID Reader Module HYM740 Winnix Technologies Co Limited ...

Страница 2: ...echnical data Unit Remark 1 Max current 1 2 A Max power output 2 Standby current 1 mA EN pin low level 3 Frequency range 902 928 MHz 4 Default working frequency Frequency hopping MHz Frequency interval 250KHz 5 Channel bandwidth 250 KHz 6 Frequency hopping speed 2 s 7 Fixed power 30 dBm 8 Stepping interval 1 2 dB 5 30dBm adjustable by software 9 Label protocol EPC C1G2 ISO18000 6C 10 Communication...

Страница 3: ...ct current 2 3 3 5 5 V GPIO Input high level 2 5 V EN 0 3 0 0 8 V GPIO Input low level 0 18 V EN Output high level 2 9 V GPIO Output low level 0 0 1 V GPIO Enable current 2 5 25 uA VEN 2V Requirement on antenna No Item Technical data Unit Remark 1 Standing wave ratio 1 5 Appearance and structure z Size 76 5 39 7 9mm z Weight 50g ...

Страница 4: ...RFID Reader Module 4 Drawing 1 Front view of the reader ...

Страница 5: ...RFID Reader Module 5 Drawing2 Side view of the reader Drawing3 Pin connector ...

Страница 6: ...design and custom services Changes or modifications made to the equipment not expressly approved by Winnix may void the FCC IC authorization to operate this equipment The use of the transceiver module is authorized in mobile or fixed host devices taking into account the conditions listed below OEM Integrator must ensure that the end user manual may not contain any information about the way to inst...

Страница 7: ...ation of this module into specific final hosts may require the submission of a Class II permissive change application containing data pertinent to RF Exposure spurious emissions ERP EIRP and host module authen ca on or new application if appropriate Feel free to contact us if additional guidance is required Manual Requirements according 15 19 RSSGEN This device complies with Part 15 of the FCC Rul...

Страница 8: ...istance of 25 centimeters is maintained between the antennas and the body of the user and nearby persons Antenna Information The HY740 includes an external antenna port Here are some design guidelines to help ensure antenna performance Never place the ground plane or route copper traces directly underneath the antenna portion of the module Never place the antenna close to metallic objects In the o...

Отзывы: