2-14
SECTION 2
DRIVING YOUR MOTOR HOME
Camping Mode Operation:
1. Unit enters CAMPING MODE after the °F/
°C button or MODE is pressed for (three) 3
seconds while in SLEEP MODE.
2. Unit displays temperature and heading for
ten (10) seconds; the display stays ‘on’ if
you continue to push either button and then
returns to SLEEP MODE ten (10) seconds
after the last button was pushed.
Nighttime Dimming:
The display brightness is lowered by 50%
when the vehicle headlights are turned on.
Calibration:
NOTE: The calibration procedure requires you
to drive your coach in a circle during
calibration mode, so you will need to be
in a large area clear of obstacles, such as
a vacant section of a parking lot.
The compass must be calibrated after its ini-
tial installation and anytime the compass sensor
is replaced or relocated. The calibration values
are saved in EPROM memory, so it is not neces-
sary to recalibrate if the battery is disconnected.
Calibration Procedure:
(Best performed in empty parking lot)
1. Press and hold the MODE button until the
words ‘ZONE’ and ‘CAL’ appear (approxi-
mately ten (10) seconds). The unit will dis-
play the current zone value.
2. Press the °F/°C button to increment the zone
value.
3. Press the MODE button to store the zone
value.
4. The unit now displays the word ‘CAL’. Press
the °F/°C button to enter the calibration
mode. The display will begin counting down
from 60 seconds and the work ‘CAL’ will
flash. Drive slowly in a circle during the 60
second calibration period. If the calibration
procedure fails, the unit will flash the word
‘CAL’ continuously. If the calibration proce-
dure is successful, the unit will display the
work ‘CAL’ for five (5) seconds and then
return to normal ignition ‘on’ operation.
ZONE ADJUSTMENT
When you travel outside the zone, the unit is
currently set ‘on’, the compass has reduced accu-
racy. To achieve maximum accuracy, it is recom-
mended to change the zone setting when
traveling to a new zone in the U.S. To change the
zone setting, follow steps (1.) through (3.) of the
CALIBRATION ROUTINE, at which point the
unit will display the word ‘CAL’. Press the
MODE button again to skip calibrating. It is not
necessary to recalibrate the compass when you
change zones.
SPECIFICATIONS
REMOTE CONTROLLED SPOT/FLOOD
LIGHT - Optional
If your coach is equipped with the remote con-
trolled spot/flood light option, the light is con-
Parameter
Min
Avg
Typ
Max
Units
Operating Voltage
9
12
18
Volts
Operating Temperature
-40
-
85
°C
Storage Temperature
-55
-
105
°C
Supply Current @12V
Active Mode
Sleep Mode
0.3
0.001
Amps
Amps
Compass Accuracy
+/-5
Degrees
Compass Resolution
45
Degrees
Temp. Measurement
Accuracy
+/-1
°C
Temperature Display
-40
-40
127
53
°F
°C
Compass zones for the U.S.
Содержание Ultimate Advantage
Страница 4: ......
Страница 5: ......
Страница 6: ......
Страница 14: ......
Страница 54: ......
Страница 66: ......
Страница 72: ......
Страница 86: ......
Страница 96: ......
Страница 126: ......
Страница 146: ......
Страница 148: ...MAINTENANCE RECORD Date Odometer Mileage Description of Service Cost...
Страница 149: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...
Страница 150: ...FUEL OIL RECORD Date Odometer Mileage Fuel Gal Oil Qts MPG Cost Date Odometer Mileage Fuel Gals Oil Qts MPG Cost...